Overview
FANGRUI CH3015 thermostatic circulating tank is a microcomputer temperature-controlled constant temperature water bath (oil bath) equipment. It adopts high-performance single-chip microcomputer control, self-tuning PID adjustment and imported temperature sensor, with high temperature control accuracy and small Fluctuation. Equipped with imported stirring motor and large-screen backlit LCD display, it has the characteristics of accurate temperature control, stability and reliability, convenient and safe operation.
Features
1. Adopt high-performance single-chip microcomputer control, PID adjustment, self-tuning control technology, high temperature control accuracy, Stabilization time is short
2. It has a break-even protection function to prevent the instrument from losing control
3, the upper limit over-temperature alarm function, can be set by yourself, beyond the range of immediate alarm
4. The instrument works stably and reliably, and the operation is very convenient
5. Large-screen backlit LCD, with clear parameters and beautiful appearance
6. The circulating pump can lead the thermostatic liquid in the tank to establish a second thermostatic field
7, liner, table are high mass stainless steel, corrosion resistance, easy to clean
Principle
Using high-performance single chip microcomputer control, self-tuning PID adjustment technology, through imported temperature sensor temperature measurement to achieve accurate temperature control. Equipped with a circulating pump can lead the thermostatic liquid outside the tank to establish a second thermostatic field.
Applications
Bioengineering, food, chemical, metallurgy, chemical analysis, petroleum, etc., can be directly thermostatic test in the water tank or connected to Miscellaneous equipment (such as Viscometer, Density Meter, surface tensiometer, Polarimeter, Rotary evaporator, spectrophotometer, etc.) through external circulation function
Steps
1. Place the equipment on a stable workbench
2. Connect the power supply and turn on the power switch
3. Set the required temperature parameters through the large-screen LCD display
4. Choose domestic circulation or external circulation mode as needed
5. Start the device to start thermostatic operation
6. Turn off the power and clean the equipment after use
Notice
• Make sure the equipment is placed on a stable bench before use
• When setting the temperature, please be careful not to exceed the maximum Temperature range of the device
• Make sure the hose connection is firm when using the external circulation function
• Regularly clean liners and countertops to maintain equipment performance
• When an over-temperature alarm occurs, check and adjust the settings in time
• Do not touch the heating part when the equipment is working to prevent burns