Overview
CHANGLONG BCW3-60 reflective temperature measuring patch is a product with discoloration temperature display, reflective display and temperature recording functions, with its own sticker. When the temperature of the monitoring part reaches or exceeds the rated temperature of 60 ° C, the patch will immediately change from white to yellow and display over-temperature numbers. Its reflective characteristics make it easy to detect temperature abnormalities during the day and night, helping to identify potential faults.
Features
1. discoloration temperature display function: when the temperature reaches 60 ° C, it irreversibly changes from white to yellow, and displays the overtemperature number
2. Reflective display: It is easy to inspect during the day and night to find that the temperature has increased
3. Bring your own sticker: easy to paste on various surfaces
4. Temperature recording: can record the overtemperature of the monitoring part
Principle
The temperature measuring patch realizes temperature monitoring through thermal sensitive materials. When the temperature of the temperature monitoring part reaches or exceeds the rated 60 ° C, the patch immediately changes irreversibly from white to yellow, and displays the over-temperature number on the patch. Combined with the reflective characteristics, the temperature abnormality can be quickly identified during the day and night.
Applications
The connection part of the bus of the substation, the connection between the bus and the terminal of the equipment, the contact of the isolator, the shell of the transformer, capacitor, motor and other electrical equipment
Steps
1. Select the surface of the part that needs to be monitored for temperature
2. Tear off the protective layer of the sticker on the back of the temperature measuring patch
3. Paste the patch on the temperature monitoring part
4. Regular inspection of patch Color change
5. If discoloration is found, record overheating and take appropriate measures
Notice
• Patch discoloration is an irreversible process, once the discoloration indicates that it has been overheated
• Make sure the surface is clean and drying before pasting to ensure the adhesion effect
Avoid use in extreme environments or chemical corrosion
• Pay attention to reflective displays when patrolling, especially at night
• For temperature monitoring only, not for accurate temperature measurement