Overview
YIHENG GMP-9050N Water-Jacketed thermostatic incubator adopts Water-jacketed Heating mode, Temperature range is RT + 5~ 65 ℃, with the characteristics of uniform temperature and thermostatic after power failure. The device is equipped with a multi-stage programmable LCD controller, which supports parameter settings such as temperature, cyclic wind speed, time and heating rate, and is suitable for experimental environments such as cell foster.
Features
1. Humanized design: brushed stainless steel liner, four corners and a half arc transition, shelf free loading and unloading; Water-Jacketed heating to ensure uniform temperature; Glass doors can be opened at any time and automatically suspended; microcomputer controller with self-tuning PID technology and temperature, water level, door alarm function.
2. Automatic control of circulating fan speed: automatically adjust the wind speed according to the thermostatic state to avoid sample volatilization.
3. LCD multi-segment programmable controller: multi-segment parameter one-screen display, menu Operating interface, support layer heating, automatic switch and other functions.
4. Safety function: independent temperature limit alarm system, sound and light alarm prompt; with low temperature, high temperature, over temperature, water shortage and long door opening time alarm.
5. Ultraviolet sterilization system (optional): can be regularly disinfected to prevent cell fostering contamination.
Principle
The incubator uses Water-Jacketed Heating mode to achieve uniform temperature distribution in the studio through the water jacket structure. The microcomputer controller uses self-tuning PID technology to precisely control the temperature to avoid temperature overshoot. The circulating fan automatically adjusts the wind speed according to the thermostatic state to ensure a suitable environment for cell growth. Multi-stage programmable functions allow users to set parameters such as temperature and time for automated operation.
Applications
Cell fostering, microbial fostering, biological experiments, medical research
Steps
1. Connect the power supply to AC220V 50Hz.
2. Set parameters such as temperature, circulating wind speed, and time through a multi-stage programmable LCD controller.
3. Install or remove the load carrier as required.
4. Start the device, and the incubator automatically controls the temperature and runs.
5. Glass doors can be opened during the experiment, and the equipment automatically pauses.
6. After use, shut down according to the program or automatically shut down by default.
Notice
• Ambient Temperature should be maintained at + 5~ 35 ℃.
• Avoid opening the door for too long to avoid triggering an alarm.
• Regularly check the water level to prevent water shortage alarms.
• When selecting a UV sterilization system, pay attention to the installation and use specifications.
• Power supply voltage must be AC220V 50Hz to ensure matching.
• When cleaning the liner, you can freely load and unload the shelf, pay attention to safety.
When using the multi-segment programming function, carefully set the parameters to avoid experimental errors.