Overview
The DOSCAN 10 pen dissolved oxygen meter is a simple and easy-to-use portable instrument from the BANTE brand for outdoor measurement of dissolved oxygen concentration and percentage Saturation of samples. The meter supports 1 or 2 point button calibrating, Measurement accuracy reaches 0.5mg/L, and is equipped with the original US Electrode Sensor to ensure accurate measurement results over the full range.
Features
1. Simple pen type dissolved oxygen meter, equipped with original American Electrode Sensor
2.1 or 2 point button calibrated for accurate measurement results over full scale
3. Optional temperature and dissolved oxygen concentration unit (mg/L or ppm), to adapt to the use habits of different countries
4. Manual salinity and atmospheric pressure compensation to improve instrument Measurement accuracy
5. Automatic temperature compensation, eliminate data deviation due to temperature difference
6. Automatic end point locking, maintaining stable readings for easy browsing or recording
7. Low battery alarm icon, prompting battery residual power
8. Automatic power off, effectively saving battery energy consumption
9. Built-in system menu, can customize the number of calibrated points, temperature units, automatic or manual data locking, timing or manual shutdown and other 6 function parameters
10. One-click reset (Reset), automatically restore the meter to the factory default settings
11. Full waterproof performance to ensure complete protection of the instrument in harsh environments
Principle
DOSCAN 10 pen dissolved oxygen meter adopts DO100 polarographic dissolved Oxygen electrode Sensor for measurement, through automatic temperature compensation, manual salinity and atmospheric pressure compensation functions, eliminate the influence of environmental factors on measurement results, and ensure the accurate reading of dissolved oxygen concentration and percentage Saturation.
Applications
Ponds and aquariums, aquaculture, water and wastewater treatment, industrial process monitoring, surface and groundwater testing, educational applications, and other industrial applications
Steps
1. Turn on the meter power
2. Select 1 or 2 point button calibrate mode to calibrate
3. Set temperature units, dissolved oxygen concentration units and other parameters as needed
4. Electrode immersion in the sample to be tested for measurement
5. Read the stable reading of the automatic lock
6. Manually turn off the power after use or wait for automatic shutdown
Notice
• Regularly check the battery power to avoid low power affecting Measurement accuracy
• Electrode cleaning before calibrating
• Pay attention to the waterproof protection of the instrument when used in harsh environments
• When not in use for a long time, it is recommended to manually turn off the power to save battery
• Use the original model when replacing Electrodes or Accessories