Measurement accuracy of +/- 0.002pH and +/- 0.5% FS with 4 measurement functions, support for 1 to 5 point calibrated and automatic identification of standard solution, built-in 500 data storage and automatic ElectRode diagnostic function.
Category : Water Quality Tester
Brand : Bante
SKU : NB014741
Service :The delivery and service By NBCLab.Com
The Bante901P-CN Portable Multi-Parameter water quality measurement instrument is a Portable pH/Conductivity Meter for outdoor measurement, with four measurement functions of pH/mV, conductivity and total dissolved solids (TDS). The instrument is equipped with a large screen backlit LCD display, supports multi-mode power supply scheme, and is suitable for rapid detection of various water quality parameters.
1. Multi-Parameter Water Quality Analyzer with a large backlit LCD screen. 2. pH mode supports 1 to 5 point button calibrate, automatically recognizes pH standard buffer, optional USA/NIST/DIN standard or custom calibrate. 3. Conductivity /TDS mode supports 1 to 5 point button calibrate, automatically recognizes Conductivity detector standard solution, selectable Electrode constant, TDS conversion factor, standardized temperature and compensation mode. 4. Automatic temperature compensation, calibrating reminder, end point lock and Electrode diagnostic function. 5. The system menu can customize 12 function parameters, and restore the default settings with one click reset. 6. Extended memory to store 500 sets of data, built-in clock conforms to GLP specifications, and USB interface to transfer data. 7. Multi-mode power supply solution (battery, Power Adapter, USB port), the battery life is about 150 hours.
The meter detects liquid parameters with pH Electrode and Conductivity detector Electrode, pH mode automatically diagnoses and calibrates with Electrode slope, conductivity /TDS mode for measurement based on Electrode constant and temperature compensation. Automatic temperature compensation ensures full scale accuracy, automatic locking after data stabilization, and storage and transfer through built-in systems.
Outdoor liquid measurement, water quality analysis, environment monitoring, laboratory testing
GLP specification
1. Turn on the meter and select Measurement mode (pH/mV, conductivity or TDS). 2. Perform 1 to 5 point calibrate as prompted, using standard buffer or standard solution. 3. Insert the corresponding Electrode (such as pH Electrode or Conductivity detector Electrode) to start the measurement. 4. The meter automatically compensates for temperature and locks stable data, which can be stored or transmitted via USB. 5. Clean Electrode after use, shut down as needed or set automatic shutdown.
• Periodically calibrate the meter to ensure Measurement accuracy. • Check Electrode Condition Before Use to Avoid Damage. • Make sure the temperature compensation is set correctly during measurement. • Pay attention to battery power when storing data to avoid data loss. • Clean and maintain Electrodes to extend service life.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.