Overview
The DDS-12DW-S Laboratory Conductivity Meter is a classic laboratory instrument of the BANTE brand, suitable for the measurement of liquid conductivity value in scientific research or testing institutions. The instrument has a 1 to 3 point button calibrate and automatic temperature compensation function. Measurement accuracy is 1% F. S, and it is equipped with a large screen LCD backlit display to ensure easy operation and accurate measurement.
Features
1. Classic Lab Conductivity Meter with large LCD backlit display.
2.1 to 3 point button calibrated to automatically identify Conductivity detector standard solution.
3. Optional Electrode constant (K = 0.1/1/10), or custom input.
4. Automatic temperature compensation to ensure accurate measurement within the full range.
5. Automatic end point locking, retaining stable Measured value for easy browsing or recording.
6. Built-in system menu, can customize the number of calibrated points, temperature units, data locking mode, shutdown mode and other 6 function parameters.
7. One-click reset (Reset), automatically restore the meter to the factory default settings.
Principle
Conductivity detector Electrode measurement of liquid conductivity, automatic temperature compensation function adjusts the Measured value according to temperature changes to ensure full scale accuracy. Built-in system supports automatic end point locking, stable display of measurement results, users can calibrate and customize parameters to optimize performance.
Applications
Water quality analysis, research and education, environment monitoring and chemical industry, other industrial applications
Steps
1. Connect the power supply and Conductivity detector Electrode.
2. Select Electrode constant or custom input after booting.
3. Perform 1 to 3 point button calibrating to automatically identify the standard liquid.
4. Set temperature compensation, data lock mode and other parameters.
5. Start measurement, the meter automatically displays and locks the result.
6. After use, the default settings can be restored by one-click reset.
Notice
• Make sure to calibrate using the specified Conductivity detector standard.
• Avoid operating in extreme temperature environments to maintain Measurement accuracy.
• Electrode and connectors are checked regularly to prevent damage from affecting performance.
• Correctly set temperature compensation and data lock mode according to application requirements.
• Clean and maintain the instrument in time after use to prolong its service life.