$ 3247.00Ex works
Adopt ALLCOLD equilibrate refrigeration technology, equipped with automatic defrosting function, temperature control accuracy of +/- 1 ℃; five-stage adjustable lighting system up to 15000LX, support multi-stage programming control, to meet the needs of long-term continuous experiments.
Category : Incubator
Brand : HengLi
SKU : NB021268
Service :The delivery and service By NBCLab.Com
The HENGLI LC-300 light chamber is a professional equipment widely used in biological tissue, cell foster, seed germination, plant planting, small animal and insect feeding and other applications. It can provide simulation of daytime and evening Illumrination degree changes and climate conditions, meet multi-stage step programming control, support long-term foster experiments, and has passed the European Union CE safety certification and enjoys a 2-year mass warranty period.
1. ALLCOLD ™ equilibrate refrigeration technology, equipped with automatic defrosting and multi-layer safety protection, energy saving and environmental protection. 2. ALLFLOW ™ air circulation system to ensure rapid temperature recovery and stability, and adjustable wind speed. 3. ALLSENS ™ microcomputer PID control technology, supports Chinese and English display, adaptive PID control and remote monitoring. 4. Pro-Bright ™ professional lighting system, simulating natural light, Illumrination degree grading adjustable. 5. Double-decked isolation insulation technology and internal isolation door design to ensure temperature conformity. 6. Humanized structural design, including movable mesh Shelf and double doors, for comfortable operation. 7. Easy to clean and maintain, liner is easy to clean, controller has diagnostic function. 8. Multiple safety protection, including over-temperature protection and sound and light alarm, in line with international standards.
The light chamber is controlled by the ALLCOLD ™ refrigeration technology implementation, using equilibrate refrigeration and fast heat pump defrosting technology to prevent frost problems. ALLFLOW ™ forced convection of the air circulation system to ensure uniform and stable temperature in the chamber. ALLSENS ™ microcomputer PID control technology precisely adjusts the temperature to prevent overshoot, and simulates day and night changes through the lighting system, and cooperates with air flow and temperature compensation to ensure a constant experimental environment.
Biological tissue fostering, cell fostering, seed germination, plant planting, small animal feeding, insect feeding
National standard, Australian AS3100, US FDA, EN, ICH, cGMP/ICH/380/95/Q1A and Q1B, European Union CE safety certification, German DIN 12880 Class 3.1 standard
Connect the power supply and ensure that the voltage is AC 220V/50Hz. 2. Open the device and select the Chinese and English interfaces through the LCD display. 3. Set the temperature range (10~ 60 ℃ without light or 10~ 65 ℃ with light) and illumination (0~ 15000LX). 4. Adjust the wind speed and light level (adjustable in five levels), and set the Timer Range (0 to 99 hours or 0 to 9999 minutes). 5. Place the sample on the movable mesh Shelf and adjust the Shelf spacing as needed. 6. Start the operation, monitor the temperature, wind speed and operating status, and connect multiple devices using the RS485 interface if necessary. 7. After the experiment, shut down the equipment and perform cleaning and maintenance.
• Ensure that the Ambient Temperature is between 10 and 30 ° C and the humidity is below 70% RH. • Power frequency matching check before use to avoid overload. • Regularly clean liners and Shelves to prevent contamination. • Pay attention to the over-temperature protection function, and deal with it in time if there is a sound and light alarm. • When the lighting system is running, avoid looking directly at the Illuminant to prevent injury. • Disconnect the power supply during maintenance to ensure safety. • Use only original imported parts, such as DuPont refrigerant, to maintain performance. • When not in use for a long time, it is recommended to save it after power failure.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.