$ 1166.00Ex works
Centrifugal wind turbine low-energy motor, noise ≤ 62dB, filtrate efficiency of 99.99%, equipped with a microcomputer control system to monitor the running status in real time, movable mesh Shelf can adjust the spacing according to demand.
Category : Laminar Flow Cabinet
Brand : HengLi
SKU : NB021293
Service :The delivery and service By NBCLab.Com
The HENGLI JHZ-1 Laminar Flow Cabinet is designed for areas such as biotechnology, life sciences and precision electronics that require product protection. It combines the good airflow mechanics design of the CLEANFLOW-JH series clean superbench to create a local purification working environment for operators to ensure smooth operation of experiments. It also complies with the Australian AS1386.5, European Union EN12469 and international ISO14644.1 standard CLASS 5 (US LIANBANG 209E, Class 100).
1. SANGMATM microcomputer control technology: integrated LCD point array large-screen LCD display, real-time display of lighting, aseptic, air volume and other parameters, with sterilization, lighting interlock function, protect the safety of operators, multi-level adjustable wind speed. 2. CLEANFLOWTM clean air technology: using centrifugal wind turbine low energy consumption motor, circular arc large diameter into the trend design, reasonable air duct and net pressure box, standard initial effect and effective double filter, effective Filter interception efficiency 99.99%, providing vertical and horizontal air flow two options. 3. Ergonomic structural design: Modern classic Color collocation, circular arc design, integration of outer door and LCD control panel, adjustable movable mesh Shelf, humanized vertical structure, double door design (incubator series). 4. Easy to clean: The liner is clean and easy to clean, with minimal splicing design, and the multi-layer shelf can be extracted for easy cleaning. 5. Easy maintenance: The LCD microcontroller has a diagnostic function, and the main control of the electrical control components is separated from the control panel for easy maintenance. 6. Safe and effective protection concept: multiple over-temperature protection functions, sound and light alarm, automatic double over-temperature safety protection, all electronic components have passed UL certification, and over-temperature protection devices comply with German DIN 12880 Class 3.1 standards. 7. Pro-BrightTM professional lighting system: simulate natural light, temperature constant compensation, three-dimensional Illuminant uniform distribution, Illumrination degree grading adjustable, lamp and liner through double-decked Glass insulation and ventilation holes for heat dissipation. 8. Provide Chinese/English IQ, OQ, PQ and a variety of verification services, through the European Union CE safety certification, enjoy 2 years mass warranty period.
Laminar Flow Cabinet adopts CLEANFLOWTM clean air flow technology, adopts centrifugal wind turbine low energy consumption motor and circular arc large diameter into the trend design to reduce turbulence and ensure low noise operation. Reasonable air duct and optimized net pressure box cooperate with the micro mesh layer to flow out the wind plate to ensure uniform and stable air flow. Standard primary and effective double filter elements, primary filter blocks dust particles, effective HEPA Filter interception efficiency reaches 99.99%, creating a local purification environment. SANGMATM microcomputer control technology monitors parameters in real time, Pro-BrightTM lighting system simulates natural light and keeps the temperature constant.
Biotechnology, Life Sciences, Precision Electronics
Australian AS1386.5, European Union EN12469, international ISO14644.1 standard CLASS 5 (US LIANBANG 209E, class 100), German DIN 12880 Class 3.1, European Union CE safety certification
1. Turn on the power and check the status of the LCD screen. 2. Adjust the wind speed and illumination as required. 3. Use sterilization and lighting interlock functions to ensure safe operation. 4. Place the sample in the working area and perform the experimental operation. 5. After the operation is completed, turn off the equipment for cleaning and maintenance.
• The working environment should be kept at a temperature of 10~ 30 ° C, relative humidity below 70%, and there is no obvious vibration and dust around. • Pay attention to UV Lamp protection when using the sterilization function to avoid burns. • Regularly clean liners and shelves to ensure equipment hygiene. • During maintenance, pay attention to the electrical control components located at the back of the box to avoid misoperation. • Timely handling of over-temperature protection device alarms to ensure safe operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.