$ 1803.00Ex works
Centrifugal wind turbine low energy consumption motor, noise ≤ 62dB, average wind speed 0.1~ 0.6m/s adjustable, equipped with initial effect and HEPA dual filtrate system to ensure uniform and stable airflow, no convex surface and no dead angle design for easy cleaning and maintenance.
Category : Laminar Flow Cabinet
Brand : HengLi
SKU : NB021294
Service :The delivery and service By NBCLab.Com
The HENGLI JHZ-2 Laminar Flow Cabinet is designed for the fields of biotechnology, life science and precision electronics that require product protection. Combined with the excellent airflow mechanics design of the CLEANFLOW-JH series clean superbench, it creates a local purification working environment for operators to ensure the smooth progress of the experiment. The product complies with the Australian AS1386.5 and European Union EN12469 standards, the cleanliness level reaches the international ISO14644.1 standard CLASS 5, and has passed the European Union CE safety certification, providing a 2-year mass warranty period.
1. SANGMATM microcomputer control technology: integrated LCD point array large-screen LCD display, real-time display of lighting, aseptic, air volume and other parameters, with sterilization, lighting interlock function, protect the safety of operators, multi-level adjustable wind speed. 2. CLEANFLOWTM clean airflow technology: using centrifugal wind turbine low energy consumption motor, circular arc large diameter into the trend design to ensure low noise operation; reasonable air duct design to ensure uniform and stable airflow; standard initial effect and effective double filter, effective Filter interception efficiency 99.99%. 3. Ergonomic structural design: Modern laboratory classic Color collocation, circular arc design to increase operating comfort; outer door and LCD control panel integrated design, adjustable movable mesh Shelf; double door design (limited to incubator series) to improve thermal insulation performance. 4. Easy to clean: The liner is clean and easy to clean, with minimal splicing design, and the multi-layer shelf can be extracted for easy maintenance. 5. Easy maintenance: The LCD microcontroller has a diagnostic function, and the main control of the electrical control components is separated from the control panel, which is convenient for maintenance. 6. Safe and effective protection concept: multiple over-temperature protection functions, sound and light alarm; automatic double over-temperature safety protection; all electronic components have passed UL certification, and the over-temperature protection device meets the German DIN 12880 Class 3.1 standard. 7. Pro-BrightTM professional lighting system: simulate natural light, uniform lighting distribution, adjustable Illumrination degree grading, lamp and liner are insulated by double-decked Glass, with ventilation holes for heat dissipation; with ALLIGENTM humidification system (limited Artificial climate box) for climate simulation.
Laminar Flow Cabinet is based on CLEANFLOWTM clean air flow technology, using centrifugal wind turbine low energy consumption motor and circular arc large diameter into the trend design to reduce disturbance and ensure low noise operation. Through reasonable air duct and optimized net pressure box, with micro mesh design layer outflow air plate, to ensure uniform and stable air flow. Standard primary effect Filter to avoid dust particles into, prolong the effective Filter life, effective Filter uses no Shelf HEPA, the interception efficiency of 99.99%. At the same time, SANGMATM microcomputer control technology monitors and adjusts parameters in real time to ensure that the operating environment is clean and safe.
Biotechnology, Life Sciences, Precision Electronics
Australian AS1386.5, European Union EN12469, International ISO14644.1 CLASS 5, American LIANBANG 209E Class 100, German DIN 12880 Class 3.1
1. Turn on the power supply and ensure that the voltage is AC single-phase 220V/50HZ. 2. Turn on the device and check the status of parameters such as lighting, sterility, and air volume through the LCD liquid crystal display. 3. Adjust the wind speed as needed and choose the appropriate air volume level. 4. Use sterilization and lighting interlock functions to ensure safe operation. 5. Place the experimental items in the work area and adjust the movable mesh Shelf according to your needs. 6. Start the Pro-BrightTM lighting system (if necessary) and adjust the Illumrination degree. 7. After the operation is completed, turn off the equipment for cleaning and maintenance.
• The working environment needs to keep the temperature 10~ 30 ℃, the relative humidity below 70%, and there is no obvious vibration and dust around. • When using the sterilization function, pay attention to UV Lamp protection to avoid burns. • Regularly clean liners and shelves to ensure equipment hygiene. • During maintenance, check electrical control components to ensure safety. • Over-temperature protection devices need to be regularly verified to prevent malfunctions. • During the use of the lighting system, pay attention to ventilating heat to avoid overheating.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.