Please contact customer service
Equipped with ultraviolet sterilization system to effectively prevent pollution, temperature control accuracy of +/- 0.3 ℃, support multi-stage programming and independent temperature limit alarm, to ensure the safety and stability of the experiment.
Category : Incubator
Brand : HuiTai
SKU : NB024708
Service :The delivery and service By NBCLab.Com
HUITAI MJ-70FN mildew incubator is a special thermostatic equipment suitable for environmental protection, agriculture, livestock, aquatic and other scientific research, institutions and production departments. It is used for water body analysis and BOD determination, the fostering and preservation of bacteria, molds and microorganisms, and plant cultivation and breeding experiments.
1. Humanized design: large-screen LCD display, multiple sets of data are displayed on one screen, and the menu-type operation interface is simple and easy to understand; the mirror stainless steel liner is easy to clean, and the shelf spacing is adjustable; the use of 134a without fluorine refrigerant, energy saving and environmental protection; there are 25mm test holes on the left side of the box for easy operation; the fan wind speed is adjusted by speed and slow gear to prevent water loss of the sample; the instrument control of the whole machine is placed in the upper left corner of the door panel to save space; the double door structure is easy to observe; the sand blasting treatment on the surface of the box is not 2. Quality assurance: brand Compressor and self-developed cooling system are used to extend the life; JAKEL tube flow circulating fan and unique air duct ensure temperature uniformity; PID control mode temperature control is accurate, with timing function up to 99 hours and 59 minutes. 3. UV sterilization system: located on the top layer of the box, effectively killing floating bacteria and preventing pollution. 4. Intelligent LCD programmable multi-stage controller (optional): 15 30-step programs can be preset, and each setting time is 1 to 99 hours and 59 minutes to achieve automatic control. 5. Independent temperature limit alarm system (optional): over-temperature automatic interruption and sound and light alarm to ensure safety. 6. Convenient data processing (optional): USB or RS485 interface can be connected to a printer or computer to record temperature changes.
Mildew incubator precisely adjusts the temperature in the box through PID control mode, with small fluctuations. Brand Compressor and self-developed cooling system are used to achieve cooling, and JAKEL tube flow circulating fan and unique air duct structure are used to establish an air circulation system to ensure uniform temperature. The ultraviolet sterilization system is located on the top floor of the box to kill floating bacteria in the circulating air to prevent pollution. Optional multi-stage controller for automatic programming control.
Environment protection, agriculture and livestock, aquatic products, scientific research, colleges and universities, production departments, water analysis, BOD determination, bacterial foster, mold foster, microbial foster, microbial preservation, plant cultivation, breeding test
no mention
Connect the power supply and ensure that the voltage is AC 220V 50Hz. 2. Open the box door and adjust the shelf spacing as needed. 3. Set the temperature parameters, Temperature range is 0~ 65 ℃, resolution 0.1 ℃. 4. Optional setting timing function, Timer Range 1~ 9999 minutes. 5. Adjust the wind speed of the fan to a fast or slow gear to prevent the loss of moisture from the sample. 6. Start the device and observe the LCD display data. 7. Optional use of ultraviolet sterilization system for disinfection. 8. After the experiment is completed, turn off the power and clean the liner.
• Power frequency check before use meets AC 220V 50Hz requirements. • Avoid running under overtemperature conditions, and an independent temperature limit alarm system can be selected to prevent accidents. • When adjusting the wind speed of the fan, pay attention to prevent the sample from losing moisture too quickly. • Use a soft cloth when cleaning the liner to avoid scratching the mirror stainless steel surface. • Regularly check whether the UV sterilization system is working properly. • Optional accessories need to be configured according to actual needs, such as program controller, temperature limit controller, etc. Do not open the door frequently when the equipment is running to maintain a stable temperature.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.