Please contact customer service
Using top LED cold Illuminant, the energy consumption is about 80% lower than that of ordinary Illuminant, and the lifespan is up to 50,000 hours. 30 programs can be set for 1-99 hours each to meet the needs of different growth stages. The horizontal circulating air design ensures uniform temperature in each layer.
Category : Environmental Chamber
Brand : hzlb
SKU : NB025342
Service :The delivery and service By NBCLab.Com
HZLB LRG-250-LED Artificial climate box (LED Illuminant) is a microcomputer program-controlled device that can accurately simulate day and night temperature, Humidity changes and provide a sufficient and stable lighting environment. Its volume is 250L, using mirror stainless steel liner and overhead LED planar lighting system, suitable for experiments and studies that require precise environment control such as plant fostering and seed germination.
1. Microcomputer program controls Temperature, Humidity, Illumrination degree, can simulate day and night changes or provide stable Illuminant. 2. 30-stage program can be set, each time range is 1-99 hours (optional), to meet the requirements of different growth stage parameters. 3. Adopt brand Compressor and R134a refrigerant to ensure long-term continuous, efficient and low energy consumption operation. 4. With anti-fog observation window and door lock, mirror stainless steel liner four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean. 5. Using cold Illuminant LED, the beam of light does not produce heat, extracting Light spectrum that is conducive to plant growth, Illuminant board size 420 * 480mm, Color temperature 4000K, 675 lamp beads per board. 6. LED Illuminant has the characteristics of miniaturization, planarization and strong designability, which can realize random arrangement of point formation and free combination of multi-color light. 7. LED energy consumption is extremely low, about 80% lower than that of ordinary Illuminant, combined with foam insulation technology to reduce the cost of use, and the warranty-free period of the whole machine is extended to two years. 8. Provide accurate and stable lighting, with a service life of over 50,000 hours and high photoelectric conversion efficiency. 9. LED Response Time is nanosecond, integrated point array Illuminant to ensure uniform coverage. 10. The light box can be easily replaced and can be used as a stand-alone Illuminant board, enabling a single box of dual-use. 11. Top-mounted planar lighting ensures uniform absorption of Illuminants by the foster and maintains the conformity of experimental results. 12. Horizontal circulating air ensures uniform temperature across layers. 13. Illuminant height adjustable shelf according to crop growth. 14. Equipped with an independent temperature limit alarm system (optional), which automatically interrupts when the temperature exceeds the limit to ensure safety. 15. The changes of each parameter can be recorded, the data can be downloaded through the U disk, and the RS485 interface can be optionally connected to the computer for synchronous monitoring (optional). 16. Can be equipped with CO2 air inlet and imported infrared CO2 controller (optional). 17. Each layer can be equipped with LED Illuminants of different Colors (optional).
The Artificial climate box is precisely programmed to control the temperature, Humidity and light in the box through a microcomputer Control system. Temperature control is achieved through the Compressor refrigeration and heating system; Humidity control is adjusted through the humidification and dehumidification system; Light is provided by an overhead LED point array Illuminant, whose Light intensity and Light spectrum can be programmed. The horizontal circulating air system ensures a uniform and stable environment in the box to simulate or create the desired growing climate conditions.
Plant fostering, seed germination, tissue fostering, insect feeding, microbial fostering, biological product testing, mass testing, scientific research
The data did not mention specific compliance criteria
1. Place the equipment in a workplace that meets the requirements (Ambient Temperature RT + 0~ 30 ℃, Humidity < 85% no corrosion gas), and connect the AC 220V 50Hz power supply. 2. Through the microcomputer control panel, set parameters such as temperature (0-50 ° C), Humidity (50-95% RH), and light intensity (0-5000-30000LX) as required, or program multi-stage operation. 3. Place the items to be fostered on the adjustable shelf and adjust the shelf height as needed. 4. Close the box door and lock it, and start the equipment to run. 5. During operation, the internal situation can be observed through the anti-fog observation window, and parameter changes can be monitored through the data recording function (e.g. optional). 6. After the experiment, remove the items and turn off the power of the device. 7. When necessary, the Shelf bracket can be removed to clean the mirror stainless steel liner.
• Equipment should work in Ambient Temperature RT + 0~ 30 ℃, Humidity < 85% and no corrosion gas environment. • Power supply voltage is AC 220V 50Hz. • Do not frequently open and close the box door during operation, so as not to affect the internal environment Stability. • When cleaning the liner, make sure the equipment is powered off and use a suitable cleaning tool. • Optional functions (such as multi-stage program, temperature limit alarm, data download, CO2 control, etc.) need to confirm that the device has been configured with corresponding modules. • If the device is not used for a long time, it is recommended to disconnect the power supply. The noise during equipment operation is less than or equal to 70dB, which is within the normal range. • Do not block the entry and exit trends of the equipment to ensure normal air circulation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.