$ 11482.00Ex works
Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.
Category : High Low Temperature Test Chamber
Brand : ZKHS
SKU : NB026927
Service :The delivery and service By NBCLab.Com
GDJS-500D high and low temperature alternating damping heat test chamber is a ZKHS brand product, suitable for aerospace products, information electronic Instruments, materials, electrical, electronic products, various electronic element gas parts in high and low temperature or heat and humidity environment inspection of its performance indicators. The equipment adopts numerical control machine tool to process the molding box, equipped with imported stainless steel liner and spray shell, which has the characteristics of beautiful and easy operation.
1. The box is processed by numerical control machine tool, which is beautiful and easy to operate 2. The inner tank of the box is made of imported stainless steel mirror plate, and the shell is sprayed with A3 steel plate 3. Replenishment tank equipped with automatic water shortage protection 4. Large observation window with lighting, using heating element embedded tempered Glass 5. The humidification system piping is separated from the control circuit board to improve safety 6. The pipeline circuit system of the water system adopts door opening, which is convenient for maintenance and repair 7. The box body insulation adopts ultra-fine fiberglass insulation cotton 8. The left side of the box is equipped with a 50mm diameter test hole 9. The temperature and humidity control instrument adopts a 7.0-inch large screen screen, which is easy to operate 10. With 100 sets of programs and 1000 segments of 999 cycle steps capacity 11. The controller has a screen lock function 12. With RS-232 or RS-485 communication interface 13. With automatic calculation function 14. The refrigerator adopts the original French "Taikang" fully enclosed Compressor 15. Adopt multi-wing blower for strong air circulation 16. The design of circulating air outlet and return air of the air duct meets the test standards
The equipment uses the original French "Taikang" fully enclosed Compressor to achieve low temperature control through the refrigeration system, and the refrigeration system adopts the unit or binary low temperature circuit system design. The heating system adopts a fully independent system and a nickel-chromium alloy electric heating heater to achieve heating, and the humidification system adopts a built-in isolated, all-stainless steel shallow surface evaporative humidifier to achieve humidity control. Through the strong air supply circulation of the multi-wing blower, the temperature and humidity distribution in the test area are uniform, and the air circulation air outlet and return air design ensures accurate and stable temperature and humidity control.
Aerospace Products, Information Electronic Instruments, Materials, Electrical, Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
1. Connect power supply AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire system Step 2 Refill the tank with water 3. Set test parameters through 7.0 inch Touchscreen controller 4. Select or edit the test program 5. Start the device and start testing 6. Monitor the test process through the observation window 7. Turn off the device after the test is completed
• Operating Environment Temperature should be in the range of 5 ℃~ + 30 ℃ • Operating Environment Humidity ≤ 85% R.H • Pay attention to check the water level of the replenishment tank to avoid water shortage • Pay attention to the safe operation of the pipeline circuit system of the waterway system during maintenance and repair • Avoid touching the controller screen artificially during testing • Pay attention to the status of the safety protection device of the equipment • Use the 50mm diameter test hole on the left side of the box when connecting the external test line
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.