Overview
SX2-12-12N integrated box type resistance furnace is a JINGQI brand periodic operation heater with a maximum temperature of 1200 ° C and a Temperature range of 100~ 1200 ° C. The product adopts an integrated temperature control design and can be used for sintering, heating and heat treatment in coal, electric power, chemical industry, building materials, metallurgy, scientific research and other units and laboratories of Universities & colleges.
Features
1. Furnace shell using cold plate by phosphoric acid film salt treatment after high temperature spray, Color is computer gray
2. The furnace is made of high aluminum liner, good wear resistance, high temperature furnace 4-sided heating up and down
3. Use thermal insulation bricks and thermal insulation cotton for heat insulation
4. Temperature measurement using K-indexed Ni-Cr-Ni-Si Thermocouple
5. PID adjustment control system, display accuracy 1 ℃
6. Brand contactor, cooling fan, solid state relay
7. Built-in secondary over-temperature protection device, over-temperature alarm, over-temperature interruption
8. Full range programmable setting, 30 program settings, automatic control of temperature rise thermostatic
Principle
The resistance furnace is heated by high temperature resistance wire, and the PID adjustment control system is used to achieve accurate temperature control. Thermocouple enters the measurement temperature from the back and top of the furnace body, and the control system connects the furnace body through compensation wires to realize the full range programmable setting and automatic control of heating thermostatic function.
Applications
Coal, Electric Power, Chemical, Building Materials, Metallurgy, R & D institutions, Universities & colleges
Steps
1. Power frequency 380V 50Hz
2. Set program parameters through the controller
3. Set temperature range 100~ 1200 ℃
4. Set the heating rate ≤ 10 ℃/min
5. Set Timer Range 0~ 9999min
6. Start the equipment to start heating operation
Notice
• Power frequency meets 380V 50Hz requirements before use
• Temperature range between 100~ 1200 ℃
The heating rate should not exceed 10 ° C/min
• Regularly check whether the over-temperature protection device is working normally
Equipment should be well ventilated during operation
• Pay attention to the temperature of the furnace body to avoid burns