$ 1463.00Ex works
With independent calibrating and 10 sets of calibrating memory functions, support continuous measurement and button trigger measurement, operation temperature range -20 ℃ to 70 ℃, IP64 Protection Rating ensures stable operation in harsh environments.
Category : Coating Thickness Gauge
Brand : Qnix
SKU : NB028234
Service :The delivery and service By NBCLab.Com
The QNix 9500Pro Coating thickness gauge is a rugged, user-friendly High Accuracy measuring instrument designed for quality control during industrial corrosion protection, lame plating and surface preparation. Manufactured in Germany, this product is equipped with advanced computer software for efficient management of documents and inspection reports, with versatility and High Accuracy.
1. High Accuracy measurement ensures effective mass results: High Accuracy measurement in the whole range, high repeatability of measurement results, Probe internal temperature compensation, to ensure the measurement accuracy on curved surfaces and small workpieces, easy calibration on rough, smooth and curved substrates 2. Solid and durable protection for long-term use under bad conditions: containing fiberglass, composed of 5 components in line with IP64, waterproof and light-proof, three-layer shock protection, LCD window glass scratch-proof, chemical-proof (H6 level), operating temperature -20 ℃ -70 ℃, stainless steel with dust-proof film Probe 3. Using ergonomic design to save time and can be used quickly and continuously without fatigue: over-limit indication, LED lamp displayed directly on LCD and Probe, highlight 24-inch LCD, can be viewed at 70 ° angle, can automatically or manually adjust the LCD luminance in sunlight to a good effect display, large size touch button and low weight medium, flip display 0 °, 90 °, 180 °, 270 ° 4. Flexibility and scalability: The host can be adapted to Fe (iron-based), NFe (non-iron-based), Fe/NFe (iron-based/non-iron-based) dual-purpose Probe, the host can be adapted to other types of Probe, both integrated Probe and split Probe, fast and convenient plug-and-play replacement Probe, fast adaptation to meet different needs 5. Easy-to-understand user-friendly interface, intuitive operation saves time and money: simple calibration for standard use, host and computer software are guided by intuitive menus, three-step reports, custom buttons, fast and direct single operation, standard pre-configuration
The QNix 9500Pro Coating thickness gauge uses magnetic Induction and eddy Current measurement principles, depending on the type of Probe connected. It supports a variety of calibrate modes, including zero calibrate, 1 point calibrate, 2 point calibrate, and independent (autonomous adjustment) calibrate, as well as manual matrix selection, automatic matrix selection, dual matrix combination measurement, continuous measurement, and key trigger measurement.
Industrial corrosion protection, lame plating, surface preparation
DIN EN ISO 2808、DIN 50981、DIN 50984、ISO 2178、BS 5411 (3 & 11)、BS 3900-C5、ASTM B 499、ISO 2360、ASTM D 1400、ASTM D 1186、ASTM D 7091
1. Select the appropriate Probe type (iron-based, non-iron-based or dual-use Probe) according to the measurement needs and plug and play connection 2. For calibrating: you can choose zero calibrate, 1 point calibrate, 2 point calibrate or independent (independent adjustment) calibrate mode 3. Select the measurement mode: manually select the substrate, automatically select the substrate, double-matrix combined measurement, continuous measurement or button trigger measurement 4. Probe placed on the surface of the workpiece for measurement, which can be triggered or delayed by pressing the button 5. Through intuitive menu operation, a test report can be generated in three steps, and the data can be exported using the USB interface
• Ensure that the Probe is properly connected to the host and avoid use in extreme temperatures (beyond the -20 ° C to 70 ° C range) • Keep Probe in stable contact with the surface of the workpiece during the calibrating and measurement process to improve measurement accuracy • Regularly check the battery level, use 2xAA alkaline dry or rechargeable batteries, and pay attention to battery life and storage conditions • Avoid Strong Impact or chemical corrosion to protect LCD window glass and Probe dust film • When using the Pin code protection function, keep the password properly to prevent unauthorized operation • In direct sunlight environment, the LCD luminance can be adjusted manually or automatically to ensure clear display
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.