Integrated compact design, parallel side open the Furnace door to keep the hot end away from the operation. Polycrystalline mullite fiber Furnace insulation, silicon carbon Rod heating, maximum temperature 1400 ℃, temperature control accuracy +/- 1 ℃, Heating time ≤ 35 minutes. With multiple safety functions such as door opening and power failure, reset delay, and over-rise alarm.
Category : Muffle Furnace
Brand : TaiSiTe
SKU : NB029236
Service :The delivery and service By NBCLab.Com
The TAISITE MFLC-18/14D ceramic muffle furnace is a high temperature heating equipment with a maximum temperature of 1400 ° C, with an all-in-one lightweight and compact design. The furnace is made of vacuum formed polycrystalline mullite fiber, which has good thermal insulation effect, and is equipped with a High Accuracy microcomputer PID temperature controller and S-type Thermocouple to ensure accurate temperature control.
1. Integrated design, lightweight and compact structure. 2. Vacuum forming polycrystalline mullite fiber furnace, effective heat preservation. 3. Adopt a parallel side open furnace door design to reduce the footprint and keep the hot end away from the operator. 4. It has the safety function of opening the door and power failure, and restarting the power delay. 5. Double shell air insulation and multi-point heat dissipation design, low surface temperature. 6. Equipped with an exhaust device, which is conducive to ashing. 7. High Accuracy Microcomputer Temperature Controller Combined with Precision Sensor, Temperature control accuracy of +/- 1 ℃, Temperature resolution of 1 ℃. 8. Realize temperature setting through dedicated function keys, making it easy to operate. 9. With auxiliary menu, it can realize over-rise alarm, deviation correction, menu locking, over-rise prevention and other functions. 10. High security, integrated with multiple protections such as over-lift alarm, menu locking, over-lift prevention, power failure when opening the door, and delay in restarting. 11. The temperature control instrument is equipped with correction function and gating function.
The muffle furnace generates heat through the internal silicon carbide heating element to heat the furnace. The furnace is made of polycrystalline mullite fiber, which has good thermal insulation performance. The temperature control is completed by the microcomputer PID controller, which receives the actual temperature signal in the furnace detected by the S-type Thermocouple, compares and calculates with the user-set temperature, and adjusts the power output of the heating element to achieve accurate temperature control and stability.
Material sintering, ashing experiment, heat treatment, ceramic processing, laboratory high temperature treatment
1. Connect the AC380V power supply to ensure good grounding. 2. Open the furnace door and place the sample to be processed. 3. Close the furnace door, and the equipment is in a safe power-off state at this time. 4. Set the target temperature and time (Timer Range 0 to 999.9 hours) by tapping the button on the thermostat. 5. Start the equipment, and the temperature controller will perform heating according to the setting program (single-stage operation). 6. During the heating process, the real-time temperature and the set temperature can be observed through the double-row LED digital display. 7. When the program is running or sampling is required, open the furnace door (automatic power failure) and operate after the furnace temperature drops appropriately. 8. After use, turn off the power.
Equipment must be reliably grounded and installed and operated by professionals. • The power requirements are AC380V/12.2A 50/60Hz, and the overcurrent and leakage protection switch of the corresponding capacity needs to be matched. • When the furnace body is working and just after the work, the surface may still be high temperature, do not touch it, and ensure that there are no combustibles around. • When opening the door, the device will automatically power off. After closing the furnace door, there will be a delay in recharging. Please do not force the operation. • Operating temperature of furnace is 1400 ℃, do not use over temperature. • Samples and crucibles placed in the furnace must be resistant to high temperature and must not come into contact with the inner wall of the furnace. • When using the vent, please pay attention to the safety of the pipeline connection. • Device weight up to 80kg (gross weight 95kg), pay attention to safety when moving and installing. • Regularly perform temperature correction to ensure temperature control accuracy. In the event of a malfunction, the power should be cut off immediately and a professional should be contacted for maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.