Please contact customer service
Adopt parallel side open Furnace door design to keep the hot end away from the operating area and improve safety. Integrated lightweight structure, equipped with polycrystalline mullite fiber Furnace effective thermal insulation, temperature control accuracy up to +/- 1 ℃, and with door opening and power failure, program operation and data export functions.
Category : Muffle Furnace
Brand : TaiSiTe
SKU : NB029268
Service :The delivery and service By NBCLab.Com
TAISITE MFLC-20/16T ceramic muffle furnace is a high temperature experimental equipment with an integrated lightweight and compact design. Its maximum Operating temperature can reach 1600 ° C, furnace volume is 20L, using silicon molybdenum rod heating elements and polycrystalline mullite fiber furnace, combined with High Accuracy Microcomputer PID control and 7-inch color Touchscreen programmed temperature control instrument, to achieve accurate temperature control and convenient operation.
1. Integrated design, lightweight and compact structure. 2. Vacuum forming polycrystalline mullite fiber furnace, good thermal insulation effect. 3. Parallel side open furnace door design keeps the hot end away from the operator. 4. Equipped with safety functions such as door opening and power failure, reset delay, etc. 5. Double shell air insulation, low surface temperature. 6. An exhaust device is provided to facilitate sample ashing. 7. High Accuracy Microcomputer Temperature Controller combined with S-type Thermocouple, temperature control accuracy of +/- 1 ℃. 8.7 inch color Touchscreen, support finger touch light point setting, display intuitive. 9. With correction function, gating function, real-time Linear dispersion recording, U disk data export and other additional functions. 10. Multiple Safety protection: over-rise alarm, menu lock, over-rise prevention, door opening and power failure, reset delay and over-current leakage protection switch.
The muffle furnace generates heat through the heating element of silicon molybdenum rod, and the heat is evenly distributed in the furnace composed of polycrystalline mullite fibers. The furnace temperature is monitored in real time by S-type Thermocouple, and the signal is fed back to the microcomputer PID temperature controller. The temperature controller precisely adjusts the Heating power through the PID algorithm according to the deviation of the set temperature and the measured temperature, so as to achieve fast and stable temperature control. The furnace body adopts a double-shell air insulation structure to effectively reduce the surface temperature.
Material sintering, ashing experiment, high temperature heat treatment, ceramic processing, metal heat treatment, laboratory analysis
The data did not mention specific compliance criteria
1. Connect the AC380V power supply. 2. Set the target temperature, heating program or timing time through the 7-inch color Touchscreen. 3. Start the heating procedure and the furnace body starts to heat up. 4. Linear dispersion can be monitored in real time through Touchscreen during operation. 5. After the experiment, wait for the furnace body to chill down naturally or cool down according to the program. 6. If you need data, you can export records through a USB stick. 7. Turn off the power.
• The device needs to use AC380V power supply, please make sure the power supply matches. • The device will automatically power off when opening the door, and there will be a delay in power back after closing the door. Please pay attention to safety. • The furnace body is at high temperature, please use special tools during operation to avoid burns. • Do not heat flammable, explosive or toxic gases in the furnace. • Regularly check whether safety devices such as overcurrent and leakage protection switches are normal. • The equipment is heavy (gross weight 230kg), so pay attention to safety when handling and installing. • Please clean the furnace in time after use and keep the equipment clean.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
