Overview
HUXI HT-X330 (set) Multifunctional Benchtop Shaker uses DC brushless motor and microcomputer control technology, and is equipped with a unique knob operation mode, which is easy to use. By changing different trays, various commonly used flasks, culture dishes, beakers can be mixed and fostered, suitable for biotechnology, microbiology and medical analysis.
Features
1. Large screen LCD display timing time, Rotation speed, temperature value, Operating interface is simple and easy to understand
2. Locked operation mode to prevent misoperation
3. DC brushless motor drive, low noise, accurate speed, long service life, maintenance-free
4. A variety of pallets, cradles, and fixtures are available for a wide range of needs
5. Accessories are easy to replace, greatly improving work efficiency
6. Soft start, accelerate evenly, effectively avoid sample splashing
7. Optional RS232 interface, connected to the computer through RS232 interface, can realize the setting of instrument parameters on the computer side and real-time display of working Linear dispersion
8. Heating series with heating speed, Temperature range, the maximum temperature can reach more than 100 ℃, make up for the lack of high temperature operation of Shaker
Principle
The multi-function Benchtop Shaker is driven by a DC brushless motor and combined with microcomputer control technology to achieve swirling oscillation. Mix and foster containers such as flask, culture dish, beaker, etc. by changing different trays. The heating series integrates oscillation and heating functions, and can rotate or reciprocate the sample, mix and foster.
Applications
Biotechnology, microbiology, medical analysis, chromadizing or decolorization of colloids, combinatorial chemistry
Steps
1. Select the appropriate tray, cradle or fixture as required
2. Place the sample container on the tray
3. Rotation speed, timing time and other parameters are set through the knob
4. Start the device for oscillation operation
5. If using the heating function, set the corresponding temperature parameters
6. Turn off the device after the operation is completed
Notice
• The maximum load of the equipment is 7.5KG, please do not overload it.
• Ambient Temperature should be within 5~ 40 ℃
• relative humidity should not exceed 80%
• Before use, please confirm that the Power supply voltage is within the range of 100~ 240V
• Make sure the device is turned off when replacing accessories
• To avoid sample splashing, it is recommended to use the soft start function