Overview
RTS-80A low temperature verification tank is a NELE brand High Accuracy automatic temperature verification device with good temperature Stability, uniform temperature field, and high temperature control accuracy. It adopts imported fully enclosed Compressor refrigeration system and intelligent PID adjustment to achieve automatic temperature control, and can be connected to computer control with RS-232 interface. The shell adopts all stainless steel structure. It is suitable for Measurement, Biochemical, Petroleum, Meteorological, Energy, Environmental Protection and other departments and thermometers, temperature controllers, temperature sensors and other Manufacturers for physical parameter detection, and can also provide thermostatic sources for Miscellaneous test research.
Features
1. High Accuracy Temperature Control, Temperature Fluctuation ≤ +/- 0.01 ℃
2. Good Temperature Field Uniformity, Temperature Uniformity ≤ 0.01 ℃
3. Adopt imported fully enclosed Compressor refrigeration system
4. Intelligent PID adjustment realizes automatic temperature control
5. Can support computer control with RS-232 interface
6. The shell is made of all stainless steel
7. Temperature range, -80~ 100 ℃
8. Fast cooling time, ≤ 120 minutes
Principle
The imported fully enclosed Compressor refrigeration system combined with intelligent PID regulation technology is used to achieve automatic and accurate temperature control. Absoluteethanol is used as the medium at low temperature, and soft water is used as the medium at high temperature (above 30 ° C). Stability and uniformity of temperature in the Tank are maintained through the intelligent Control system.
Applications
Measurement, biochemical, petroleum, meteorology, energy, environmental protection, thermometer production, temperature controller production, temperature sensor production
Steps
1. Connect the 220V 50HZ power supply
2. Select the appropriate medium according to the Temperature range (absoluteethanol for low temperature, soft water above 30 ° C)
3. Set the required temperature parameters
4. Start the equipment to start the cooling process
5. Can be remotely controlled by connecting to a computer through the RS-232 interface
6. Start the detection work after the monitoring temperature is stable
Notice
• Power supply voltage 220V 50HZ before use
• Choose the medium correctly according to the Temperature range: use absoluteethanol at low temperature and soft water at high temperature (above 30 ° C)
• Device weight up to 150kg, pay attention to safety when handling
• The process of rising and cooling takes ≤ 120 minutes, please arrange the use time reasonably
• Regularly check the working status of the refrigeration system
Keep the working environment well ventilated