Temperature range -40~ 100 ℃, Temperature Fluctuation +/- 0.03 ℃, with internal and external circulation function, hidden chill down coil design, intelligent PID temperature control system to ensure temperature Stability.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB035945
Service :The delivery and service By NBCLab.Com
TENLIN DC-4015 Vertical Low Temperature Circulating Bath is a precision temperature control device with a Temperature range of -40~ 100 ° C and a Tank volume of 15L. It adopts self-developed temperature control technology, featuring High Accuracy and High Stability, and is suitable for various experiments and test scenarios that require precise temperature control.
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components. 2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate temperature display. 3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃. 4. With over-temperature protection and alarm function, the alarm temperature can be set, and the load can be automatically cut off when the temperature is exceeded. 5. With timing function, the total working time of the equipment can be set, and the load can be automatically cut off at that time. 6. Adopt hidden chilled down coil design to ensure larger space in the groove. 7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, special users can also manually adjust. 8. Use software digital lock Control system settings to avoid misoperation and ensure accurate experimental data. 9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent. 10. Standard internal and external circulation function, external circulation import and export outer diameter 10mm round tube. 11. Support non-standard customization.
The device monitors the temperature of the medium in the Tank in real time through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the Power output of the heating and cooling system (fully enclosed Compressor) for precise control and stability of the temperature in the tank. Standard internal and external circulation pumps circulate the thermostatic medium to external devices for extended Temperature range.
Bioengineering, Pharmaceutical Research, Chemical Synthesis, Material Testing, Physical Experiments, Measurement calibrating, Petrochemicals
1. Place the device in a smooth and ventilated place and connect it to the power supply. 2. Inject an appropriate amount of suitable medium (e.g. silicone oil, ethanol, etc.) into the Tank. 3. Turn on the power switch and set the required target temperature, over-temperature alarm temperature and timing duration through the control panel. 4. Start the equipment, start the refrigeration/heating system, and adjust the medium temperature to the set value. 5. After the temperature is stable, the sample or container to be thermostatic can be placed in the Tank, or connected to the external circulation line for external temperature control. 6. After the experiment, turn off the power of the equipment, take out the sample, and do a good job of cleaning and maintenance.
Equipment should be placed in a stable, well-ventilated environment, away from flammable and explosive items. ● Please select the appropriate medium in the tank according to the Temperature range before use, and ensure that the liquid level is within the safe range. Do not start the heating function when there is no medium or insufficient medium in the tank to avoid damage to the equipment. ● When the equipment is running, do not directly touch the medium in the groove, chill down the coil and heating parts to prevent burns or frostbite. ● When performing external circulation operations, please ensure that the pipeline connection is firm and there is no leakage. ● Regularly check and clean the equipment to keep the entry and exit trends open. If it is not used for a long time, please empty the medium in the tank and disconnect the power supply.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.