Volume up to 800L, Illumrination degree 0-12000LX adjustable, can simulate natural lighting environment. Microcomputer programming control, Temperature uniformity +/- 1 ℃, with power-off memory and multiple Safety protection functions.
Category : Incubator
Brand : HongKe
SKU : NB036825
Service :The delivery and service By NBCLab.Com
HONGKE GHP-800 intelligent light chamber is a device used for cell tissue growth and cultivation, seed germination, seedling, insect and small animal feeding and microbial foster preservation. It adopts microcomputer control technology to simulate the natural light environment by setting parameters such as temperature, Illumrination degree and time. It is suitable for thermostatic and light experiment fostering in bioengineering, medical research, agricultural science and other fields.
1. Microcomputer automatic control, easy to operate touch switch, programmable control of a variety of parameters (temperature, Illumrination degree and time), to achieve day and night cycle work. 2. PID output control, the temperature and Illumrination degree can be set separately during the day and night, Illumrination degree multi-level adjustable (0~ 12000LX), with power-off memory function. 3. Intelligent thermostatic Control system Response fast, high temperature control accuracy (Temperature resolution 0.1 ℃), air duct ventilating make the studio wind speed soft, uniform temperature (uniformity +/- 1 ℃). 4. With ultra-temperature Sensor abnormal protection function, and an independent air duct over-temperature protection device to ensure the safe operation of the instrument. 5. The four corners of the inner tank of the box are semi-circular arcs, using imported mirror or brushed stainless steel. Appearance is generous, well-made and good thermal insulation performance.
Control system is used to program parameters such as temperature, Illumrination degree and time. Intelligent thermostatic control and PID output, combined with air duct ventilating system, can achieve uniform temperature and fast Response in the working room. The lighting system can simulate the natural lighting environment and cycle day and night through adjustable illumination to provide suitable thermostatic and lighting conditions for biological growth or preservation.
Bioengineering, medical research, agricultural sciences, aquatic products, animal husbandry
1. Turn on the power supply (220V 50Hz) to ensure that the working Ambient Temperature is within the range of 5~ 35 ℃. 2. Start the device through the touch switch and enter the microcomputer control interface. 3. According to the experimental requirements, the temperature (10-50 ° C when there is light, 5-50 ° C when there is no light), Illumrination degree (0~ 12000LX adjustable) and time (Timer Range 1~ 9999 minutes) can be programmed to set the cycle mode of day and night separately. 4. Place the sample to be fostered or preserved on the shelf (standard 3 pieces) and close the box door. 5. The equipment starts to run, the intelligence system automatically controls the temperature and light, and simulates the setting environment. 6. After the experiment, turn off the device according to the program or wait for the timing to end.
• Before use, make sure that the Power supply voltage is 220V 50Hz and check whether the equipment is well grounded. Equipment should be placed in a well-ventilated, Ambient Temperature 5~ 35 ℃ stable place, avoid direct sunlight or close to heat sources. • When setting parameters, please pay attention to the Temperature range: 10-50 ° C under light conditions, 5-50 ° C under no light conditions, do not use beyond the limit. • During operation, do not frequently open and close the box door, so as not to affect the temperature and light Stability. • Regularly clean the liner (imported stainless steel material) to keep the box hygienic, but it needs to be operated without power when cleaning. • If the device alarms (such as over-temperature protection), please check the Sensor and setting parameters first, and then use it after troubleshooting. • Non-professionals should not disassemble or repair the equipment, and operations involving refrigerants (such as R134a) should be carried out by professionals. • When not in use for a long time, please disconnect the power supply, wipe the box clean, and keep drying.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.