Please contact customer service
Infrared NDIR Sensor, detection accuracy ≤ 3% F. S, Response Time ≤ 30 seconds. With automatic temperature compensation, full software Adjustment, support 4-20mA analog and RS485 digital signal output, convenient System integration.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB036985
Service :The delivery and service By NBCLab.Com
SK/MIC-600-CO-Y/100% online carbon monoxide detector is a fixed installation gas concentration monitoring equipment of SKYEAGLEE brand. The instrument adopts Modular design, intelligent Sensor detection technology and overall flameproof (d) structure. The standard configuration includes point array LCD liquid crystal display, three-wire 4~ 20mA analog and RS485 digital signal output, and can customize programmable switch output and other modules according to user requirements. Output signal fine-tuning is supported, which is convenient for system networking and maintenance.
1. Modular design, Intelligent Sensor detection technology and integral flameproof (d) structure. 2. With automatic temperature compensation, zero point and full scale drift compensation function. 3. Impact protection against high concentration gases. 4. Support full software calibrate, users can calibrate by themselves through 3 buttons, easy to operate. 5. Provide 2-wire 4-20mA Output signal. 6. Standard configuration with dot matrix LCD liquid crystal display, support three-wire system 4~ 20mA analog and RS485 digital signal output. 7. Programmable switch output and other modules can be customized according to user requests, and support Output signal fine-tuning.
The detector adopts the principle of infrared NDIR Sensor to continuously monitor the concentration of carbon monoxide (CO) in the environment through Sampling methods such as diffusion, pipeline, flow or pump suction. The Sensor converts the gas concentration signal into an electrical signal, and after processing, it can output 4-20mA current signal or RS485 digital signal, and can display the concentration value in real time through the LCD display screen.
Paints room, incinerator, scientific research, production workshop, company, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, petroleum and petrochemical, chemical plant, smelter, steel plant, coal plant, thermal power plant, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, safety protection equipment monitoring in dangerous places, etc.
Explosion-proof marking: ExdIICT6
1. Installation: Select the diffusion, pipeline, circulation or pump-suction Installation method according to the site conditions, and connect the cable as required (Shielding cable is recommended). 2. Wiring: Connect the power supply (DC12~ 30V) and Output signal line (4-20mA, etc.) according to the electrical wiring definition diagram. 3. Power on: Turn on the power supply, start the device and perform self-test. 4. Calibrate: Use the 3 buttons on the device to enter the calibrate mode, and calibrate the zero point and range according to the full software calibrate process. 5. Settings: Set parameters such as alarm points as needed. 6. Operation: The device starts to continuously monitor and display the concentration, and output the corresponding signal.
• Please select and install according to the actual working conditions. • Operating ambient temperature range is -20 ℃~ + 50 ℃, Humidity range is 10% RH~ 90% RH (no condensation). • Operating absolute pressure range is 106KPa +/- 20KPa. • It is recommended to use Shielding cable for connecting cables, with a single wire diameter of not less than 1.5mm and a connection distance of not more than 1000 meters. • Sensors have a lifespan of approximately 2 years and require regular maintenance and calibrating. Equipment Protection Rating is IP66, but care should be taken to avoid extreme environments when installing. • Alarm points are settable items and need to be reasonably configured according to safety specifications. • The information is for reference only, please refer to the product manual for specific operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.