Overview
The TP3117 Benchtop Multi-Parameter analyzer is a powerful and easy-to-use precision Benchtop analyzer from the TIMEPOWER brand. It can quickly determine COD, ammonia nitrogen, total phosphorus, total nitrogen, turbidity, suspended solids (SS) and other parameters in enterprise wastewater.
Features
1. Adopt 5.0-inch large-screen LCD display, key operation, direct data reading, simple and time-saving operation.
2. Imported Cold Illuminant, Good Optical Properties, Life up to 100,000 hours.
3. Standard measurement or Continuous Measurement mode can be selected to choose between rapidity and accuracy.
4. Colorimetric tube is used for simple, fast and safe determination.
5. Built-in thermal printer, which can print current data and historical measurement data.
6. Memory standard working Linear dispersion and 96 user-defined Linear dispersion, can store 30,000 detection data, with data storage and power-off protection functions.
7. Equipped with a dedicated detection Reagent to minimize user operation and make detection more accurate.
8. Consumables are inexpensive and used in small quantities.
9. Support network port, USB interface, and can transfer data with PC or printer.
Principle
The instrument uses the photoelectric Colorimetric principle for measurement. According to the Lambert-Beer law: when a beam of monochromatic parallel light passes through a colored solution, part of the light energy is absorbed by the solution. If the thickness of the liquid layer remains unchanged, the degree of light energy absorbed is proportional to the concentration of the colored substance in the solution.
Applications
Emergency monitoring, sewage treatment, chemical, pharmaceutical, petrochemical, coking, papermaking, metallurgy, brewing, medicine, food, printing and dyeing, Eletroplating, water treatment, R & D institutions, colleges and universities
Notice
• In order to improve the accuracy of testing, the interaction between samples during testing should be reduced, and the blank, master standard, digestion tube and tube cover of the sample should be fixed to reduce the error caused by operation.
• According to the concentration value of the tested sample, the corresponding standard Linear dispersion should be selected.
• Since the oxidation agent contains a chloride ion masking agent, there may be a small amount of settling after digestion. When Colorimetric, do not shake the digestion Colorimetric tube to avoid settling and floating, resulting in deviation of results.