Overview
YIHENG MGC-400B light Chamber is a high-efficiency and energy-saving equipment, using imported brand Compressors and circulating fans, with low energy consumption, low noise, and more than 40% cooling time compared with traditional low-temperature equipment. It is widely used in microbial tissue cell fostering, seed germination, seedling testing, plant cultivation, and insect and small animal feeding, and can accurately simulate different environment climate conditions.
Features
1. Microcomputer program to control temperature, Humidity, Illumrination degree, can simulate day and night temperature, Humidity changes, or choose stable Illuminant.
2. Large-screen LCD display, multiple sets of data are displayed on one screen, and the menu-type Operating interface is simple and easy to understand.
3. Imported brand Compressor to ensure long-term continuous operation, environmentally friendly refrigerant effective low energy consumption.
4. Mirror stainless steel liner, four corners and half arc transition, Shelf bracket free loading and unloading for easy cleaning.
5. 30 sets of programs can be set, each set time range is 1-99 hours (optional).
6. Independent temperature limit alarm system, automatic interruption over temperature to ensure safety (standard).
7. Can be equipped with RS485 interface and computer connection to monitor the experimental process or record data (optional).
8. Can be equipped with CO2 intake and CO2 controller (infrared CO2 Sensor) to promote plant growth.
Principle
The light Chamber uses microcomputer programs to precisely control temperature, Humidity and Illumination, simulating day and night environment changes. Imported Compressors and circulating fans are used to achieve efficient cooling and air circulation, ensuring stable internal climate conditions and promoting plant growth with an optional CO2 system.
Applications
Microbial tissue cell fostering, seed germination, nursery experiments, plant cultivation, insect and small animal feeding
Steps
Connect the power supply and ensure that the voltage is AC 220V 50Hz.
2. Turn on the power of the device and perform menu operations through the large-screen LCD display interface.
3. Set Temperature, Humidity and Illuminance parameters, you can choose to simulate day and night changes or stabilize Illuminant.
4. Set program groups as needed (up to 30 groups, each group lasts 1-99 hours, optional).
5. Place the sample on the shelf and start the equipment to run.
6. Monitor the experimental process, and connect to the computer to record data through the RS485 interface (optional).
7. After the experiment, turn off the power and clean the liner.
Notice
• Ambient Temperature should be kept within the range of + 5~ 30 ℃.
• Continuous Operating Time of not less than 180 hours to avoid overload operation.
• Check the function of the independent temperature limit alarm system before use to ensure safety.
• When cleaning the liner, you can freely load and unload the Shelf bracket, and pay attention to avoid sharp objects scratching the mirror stainless steel.
• Optional features such as Program settings, RS485 interface and CO2 system need to be configured according to actual needs.
• Power supply voltage must match AC 220V 50Hz to prevent equipment damage.