$ 4024.00Ex works
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with 120 groups of programmable control and a variety of Safety protection functions, support data export and remote monitoring.
Category : High Low Temperature Test Chamber
Brand : YiHeng
SKU : NB038680
Service :The delivery and service By NBCLab.Com
A new generation of high and low temperature (alternating) test Chamber, the company has many years of successful experience in box design, in line with the humanized design concept, starting from the actual needs of customers, in every detail to meet customer requirements, to provide customers with high-quality products.
1. Humanized design: The new fluorine-free design makes you always walk in front of healthy life; Imported temperature Humidity controller has long life, High Accuracy CFL20 word × 6 line LCD display, keyboard input, easy operation; There is a 25mm diameter or 50mm test hole on the left side of the box, which is convenient for experimental operation and Measuring temperature. 2. Quality assurance: imported brand Compressor and circulating fan, so that the temperature distribution is uniform; high efficiency of environmentally friendly refrigerant, low energy consumption, promote energy saving; unique air duct circulation system to ensure uniform working room temperature Humidity; imported 304 mirror stainless steel liner, four corners and a half arc over, shelf bracket can be freely loaded and unloaded, easy to clean the box; multi-stage programmable control, can simplify the complex test process, truly realize automatic control and operation. 3. Safety function: independent temperature limit alarm system, if the temperature exceeds the limit, the operation will be automatically interrupted, and the sound and light alarm will prompt the operator to ensure the safe operation of the experiment without accident; high temperature, low temperature and over-temperature alarm; Compressor overheating, overcurrent, overload protection, fan overheating protection, etc. 4. Convenient data processing (optional): can be connected to a printer or 485 Communication interface, with USB data transfer interface (SD disk), display with a computer, and print Humidity and Time Linear dispersion, providing a strong guarantee for data storage and playback during the test process. 5. Programmable Touchscreen Controller (BPHJ series standard): Adopt color LCD touch control screen, menu-type Operating interface, intuitive observation and easy operation; Operating interface in Chinese and English can be selected arbitrarily, and the screen can display immediate Temperature Humidity Run Linear dispersion; can be set up 120 groups of 99 segments each, 999 cycles, each segment can be set for 999 hours 59 minutes, 59 seconds; with screen lock function to avoid human touch and change the test data or stop; with P.I.D automatic calculation function, can immediately correct the temperature Humidity change conditions, making the temperature Humidity control more accurate and stable; with RS-232 or RS-485 Communication interface, can design programs on the computer, monitor the test process and perform functions such as switching machine; Installing professional control software on the computer allows for the simultaneous monitoring and control of 30 devices. Analyze and store data in real time on the computer to form Excel documents or Word documents for easy printing.
Through imported brand Compressors and environmentally friendly refrigerants to achieve high-efficiency refrigeration, combined with a unique air duct circulation system, the working room temperature Humidity distribution is uniform; programmable controller is used to correct the temperature Humidity change in real time through the P.I.D automatic calculation function to ensure accurate and stable control; independent temperature limit alarm system and multiple protection mechanisms are used to ensure the safe operation of equipment.
High and low temperature environment simulation test, alternating temperature Humidity test, product Reliability verification, material performance evaluation, electronic component aging test, accelerated weathering of automotive parts, aerospace equipment environmental adaptability test, medical apparatus Stability inspection, chemical product storage conditions simulation, scientific research experiment Temperature Humidity control
no mention
1. Connect the power supply AC220V 50Hz to ensure that the device is powered on. 2. Enter the Humidity parameter through the keyboard or Touchscreen, and set the number of programmable segments (up to 120 groups of 99 segments per group). 3. Start the equipment, the Compressor, circulating fan and air duct system start to work to achieve temperature and Humidity control. 4. Real-time monitoring of temperature and Humidity Run Linear dispersion, observe the data through LCD display or computer software. 5. Use the test hole for experimental operation and temperature measurement. 6. After the experiment is completed, connect the printer or computer through the Interface to export and store the data. 7. When cleaning the studio, the loading and unloading shelf brackets are cleaned.
• Avoid artificially touching the screen to change the test data, and use the screen lock function. • Pay attention to the temperature alarm. When the temperature exceeds the limit, the equipment will automatically interrupt operation and give an audible and visual alarm. • Regularly check the Compressor, fan and other components to prevent overheating, overcurrent and overload. • Use environmentally friendly refrigerants to ensure a fluorine-free design that meets health and environmental requirements. When installing professional control software on your computer, ensure compatibility and a stable connection. • Keep the test hole unobstructed during the experiment for easy operation and measurement.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.