Overview
A new generation of high and low temperature (alternating) test Chamber, the company has many years of successful experience in box design, in line with the humanized design concept, starting from the actual needs of customers, in every detail to meet customer requirements, to provide customers with high-quality products.
Features
1. Humanized design: Fluorine-free design, long life of imported temperature and Humidity controller, High Accuracy CFL20 word × 6 line LCD display, easy keyboard input operation, test hole on the left side of the box for experimental operation and Measuring temperature.
2. Quality assurance: imported brand Compressor and circulating fan make the temperature distribution uniform, environmentally friendly refrigerant efficiency is high and energy consumption is low, the unique air duct circulation system ensures uniform working room temperature Humidity, using imported 304 mirror stainless steel liner for easy cleaning, multi-stage programmable control to achieve automatic control and operation.
3. Safety function: independent temperature limit alarm system automatically interrupts operation and sound and light alarm, high and low temperature and over-temperature alarm, Compressor overheating overcurrent overload protection, fan overheating protection.
4. Convenient data processing (optional): can be connected to a printer or 485 Communication interface, with USB data transfer interface, display and print with a computer Humidity and Time Linear dispersion.
5. Programmable Touchscreen Controller (Standard): Color LCD Touchscreen Menu Operating interface, Chinese and English Operating interface optional, can set up 120 groups of 99 segments 999 cycles, screen lock function, P.I.D automatic calculation function, RS-232 or RS-485 Communication interface, professional control software can monitor and control 30 devices at the same time, real-time analysis and storage of data to form Excel or Word documents.
Principle
The product adopts imported Compressor and circulating fan, combined with environmentally friendly refrigerant and unique air duct circulation system to achieve uniform temperature distribution in the studio. Multi-stage programmable control is carried out through programmable Touchscreen controller, which automatically adjusts temperature Humidity, and has P.I.D automatic calculation function to ensure accurate and stable thermal insulation Humidity control.
Applications
High and low temperature alternating test, environment Reliability test, product durability test, quality control and R & D experiment
Steps
1. Connect the power supply to AC380V 50Hz.
2. Enter the Humidity parameter via keyboard or Touchscreen.
3. Set the number of programmable segments and cycles.
4. Start the equipment operation test.
5. Measuring temperature through the test hole.
6. Use the Interface to connect to a computer for data monitoring and storage.
Notice
• When the temperature exceeds the limit, the equipment will automatically interrupt operation and alarm, which needs to be dealt with in time.
• Avoid touching the screen lock function artificially to prevent changing test data or downtime.
• Check whether the Compressor, fan and other protection functions are normal before use.
• Regularly clean the studio with removable shelves for easy maintenance.
• When selecting the data processing function, ensure that the interface connection is correct.