Overview
BENTING BGDW-100 low-temperature test chamber is used for Reliability test of high, low temperature, constant heat and humidity of industrial products. The equipment can inspect various performance indicators of parts and materials of related products such as electronics and electricians, automobiles and motorcycles, aerospace, ship weapons, colleges and universities, R & D institutions, etc. The product has a wide temperature control range, and its performance indicators meet the technical conditions of the national standard GB10592-89 low/high temperature test chamber.
Features
1, BENTING has independent intellectual property rights and Appearance design and master the core technology of environmental test chamber.
2. The control instrument adopts Taiwan Weilun "TK1200" series, Chinese Simplified Operating interface, optional R232/485 Communication interface.
3. The refrigeration system adopts the original French Taikang Compressor unit.
4. The core electrical components are made of well-known domestic and foreign brands such as Schneider.
Principle
The test chamber is precisely controlled by a microcomputer temperature integrated controller, using a nickel-chromium alloy electric heating heater to heat up, cooling through a fully enclosed Air-Cooled compression refrigeration system (single stage or cascade), and is driven by a high temperature and low noise centrifugal motor Multi-leaf centrifugal wind turbine to achieve air circulation in the box to simulate and maintain the set high, low temperature or constant heat and humidity environment.
Applications
Electronics and electricians, automobiles and motorcycles, aerospace, ships and weapons, colleges and universities, R & D institutions
Standards
GB 2423.1, GB 2423.2, GB 2423.3, GB 2423.4, GJB150.3, GJB150.4, IEC, MIL standards
Steps
The information does not provide specific operation steps.
Notice
* Power supply voltage must be AC380V +/- 10% 50HZ.
* Ambient Temperature should be in the range of 5~ 30 ℃.
* Environmental humidity should be ≤ 85% R.H.
* Equipment with leakage, short circuit, overtemperature, compression overvoltage, overload, overcurrent and other multiple Safety protection devices, but still need to pay attention to safety when operating.