$ 19518.00Ex works
Adopt multi-channel mechanical compression refrigeration system and frequency conversion technology to achieve 5 ° C/min linear temperature rise and drop; Equipped with capillary tubing throttle system to ensure temperature uniformity, fluctuation +/- 0.5 ° C; Improve control accuracy and Stability through forced air duct and PID adaptive algorithm.
Category : High Low Temperature Test Chamber
Brand : HUDA
SKU : NB041435
Service :The delivery and service By NBCLab.Com
HUDA QD-E708-1000K60-X5 rapid temperature change test chamber is a professional equipment used to determine the adaptability of electronic products, automotive parts, materials, etc. under the conditions of high humidity, low humidity, constant heat and humidity, high and low temperature rapid alternating cycle, surface condensation heat and humidity. The testing machine adopts reasonable structure and stable and reliable Control mode, has the characteristics of beautiful appearance, simple operation, safety, high temperature and humidity control accuracy, and is an ideal equipment for rapid temperature change test, constant temperature and humidity test, and alternating cabinet humidity test.
1. Adopt multi-channel environmental protection and energy-saving mechanical compression refrigeration system, energy consumption only accounts for 80% of congeneric products, low noise operation is achieved through frequency conversion technology and sound absorption and silencing design 2. Self-developed multi-channel multi-stage throttling system, automatically adjusting capillary tubing throttling through intelligent control to ensure adjustable flow and uniform temperature field 3, the application of broadband compression equilibrating temperature control system, using fast convergence PID adaptive algorithm to achieve rapid temperature control 4. Configure human-machine management interface and RS485 communication, support remote visual control, with automatic fault prompt and graphical troubleshooting guidance
The equipment selects the refrigeration path adaptively according to the working conditions through a multi-channel mechanical compression refrigeration system and a self-developed multi-stage throttling system. The broadband compression equilibrate temperature control system is adopted, and the temperature reconciliation chamber, static pressure chamber and centrifugal fan blade forced air duct system are used to ensure full exchange of hot and cold and uniform air supply to the studio. The control system adopts PID adaptive algorithm to correct the temperature control in real time to achieve fast convergence and stable control.
Electronics, automotive parts, materials
GB2423.1-2008/IEC6008-2-1-2007、GB/T 2423.2-2008、GJB150.3A-2009、GJB150.4A-2009、GB2423.22-2008、GBT 2424.5-2006、GB/T 10589-2008、GB/T2423.3-2008(IEC68-2-3)、GJB150.9A-2009、G/BT 2423.4-2008/IEC6008-2-30:2005、GB/T5170.18-2005、GB/T10586-2006、GBT 2424.6-2006、GBT 2424.7-2006
1. Ensure that the installation site meets the requirements: the ground is flat, well ventilated, no flammable and explosive gases, and the load-bearing capacity is not less than 600kg/m ² 2. Connection power supply: AC380V three-phase four-wire system + protective grounding, voltage fluctuation range of 10%, frequency 50 +/- 0.5Hz 3. Water supply system connection: using automatic/manual dual water supply mode, the water quality must meet the second-level water use standard of the National Analytical Laboratory 4. Set the test parameters through the touch screen controller: you can choose the program mode or the fixed value mode to run 5. Start the equipment operation and monitor the real-time data of temperature and humidity 6. After the test is completed, shut down according to the program
• The installation site must be free of flammable, explosive, corrosive gases and dust • Maintenance space needs to be left around the equipment: not less than 400mm on both sides, and not less than 1000mm behind • Power supply voltage allowable fluctuation range is 10%, frequency fluctuation range is 50 +/- 0.5Hz • Protective ground wire grounding resistance must be less than 4Ω • The water quality of the water supply meets the secondary water standard of the National Analytical Laboratory, and the solid impurity content is less than 1mg/L The working environment temperature should be kept at 5~ 30 ℃, humidity ≤ 85% R.H. • The equipment has multiple protection devices. If there is a failure, it needs to be eliminated according to the prompts before running. • The whole machine needs to be shipped during transportation to avoid violent vibration
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.