$ 13064.00Ex works
The multi-channel mechanical compression refrigeration system saves up to 20% energy, is equipped with a 512L studio and a rapid temperature change rate of 5 ° C/min, and guarantees temperature uniformity through a forced air duct system. It supports 120 sets of program capacity and remote visual control.
Category : High Low Temperature Test Chamber
Brand : HUDA
SKU : NB041426
Service :The delivery and service By NBCLab.Com
HUDA QD-E708-512K40-X5 rapid temperature change test chamber is used to determine the adaptability of electronic products, automotive parts, materials, etc. under the conditions of high humidity, low humidity, constant heat and humidity, high and low temperature rapid alternating cycle, heat and humidity of surface condensation. The equipment adopts reasonable structure and stable and reliable Control mode, with beautiful appearance, easy operation, safety, high temperature and humidity control accuracy. It is a professional equipment for rapid temperature change test, constant temperature and humidity test, alternating humidity cabinet test.
1. Adopt multi-channel, environmentally friendly and energy-saving (low noise) mechanical compression refrigeration system, use environmentally friendly materials and two-stage multi-channel main bypass system, combined with frequency conversion technology to achieve energy saving, low noise and High Accuracy control. 2. The self-developed multi-channel and multi-stage throttling system automatically adjusts the capillary tubing throttling through the intelligent control system to ensure adjustable flow and uniform temperature field. 3. Applying broadband compression equilibrating temperature control system, combined with fast convergent PID adaptive algorithm, to achieve fast control and uniform distribution of temperature. 4. Realize remote visual control, equipped with man-machine management interface and RS485 communication interface, support graphical operation and automatic fault prompt.
The equipment automatically adjusts the refrigeration output and flow rate according to the working conditions through a multi-channel mechanical compression refrigeration system and a multi-stage throttling system to achieve rapid temperature change and uniform distribution. The broadband compression equilibrate temperature control system and PID adaptive algorithm are used to ensure the full exchange of hot and cold and uniform air supply to the studio through the forced air duct system of the temperature harmonizing chamber, static pressure chamber and centrifugal fan blade. The control system is continuously revised according to the temperature situation to achieve fast convergence and stable control.
Electronics, automotive parts, materials
GB2423.1-2008/IEC6008-2-1-2007、GB/T 2423.2-2008、GJB150.3A-2009、GJB150.4A-2009、GB2423.22-2008、GBT 2424.5-2006、GB/T 10589-2008、GB/T2423.3-2008(IEC68-2-3)、GJB150.9A-2009、G/BT 2423.4-2008/IEC6008-2-30:2005、GB/T5170.18-2005、GB/T10586-2006、GBT 2424.6-2006、GBT 2424.7-2006
1. Ensure that the installation site is flat, well ventilated, free of flammable and explosive gases, and check the Power supply voltage and grounding. 2. Connect the water supply system to ensure that the water quality meets the requirements, and choose the automatic or manual water supply mode. 3. Set the temperature and humidity parameters through the control panel, and you can choose the program mode or the fixed value mode to operate. 4. Start the equipment, monitor the running status, and view real-time data and fault prompts through a graphical interface. 5. After the test is completed, turn off the equipment and disconnect the power supply for daily maintenance.
• The installation site should be flat and well ventilated to avoid flammable, explosive and corrosive gases. • Power supply voltage stability, grounding resistance is less than 4Ω. • The water quality of the water supply must meet the second-level water use standard of the National Analytical Laboratory. • When the equipment is running, there should be enough maintenance space around. • Regularly check the refrigeration system and protective devices to prevent excessive temperature or pressure. • Avoid using the device in extreme environment temperatures (below 5 ° C or above 30 ° C).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.