Overview
YM2003J Density Electronic Balance is a High Accuracy Density measuring instrument launched by Shangtian Jingyi brand. It adopts a new generation of Sensor technology to provide stable and reliable weighing results. The product has Density direct reading function, the reaction time is less than 3 seconds, and it is suitable for rapid measurement of various parameters such as liquid Density, Baume and concentration.
Features
1. Adopt a new generation of High Accuracy Sensors to ensure stable and reliable weighing results
2. Equipped with backlit high definition LCD LCD display, the display is clear and easy to read
3. Front horizontal bubble adjustment design, simple and intuitive operation
4. Density direct reading function, response time is less than 3 seconds
5. Density upper and lower limits and specific gravity parameter customization
6. Liquid Density, Baume, concentration and other parameters can be measured
7. Standard RS232 interface, optional PC-STWC function to realize data direct transmission to Excel and other applications
8. Wide voltage power supply design, support 110V-240V, 50Hz/60Hz
Principle
The Density Electronic Balance is based on High Accuracy Sensor technology, which weighs the sample and automatically calculates the Density value. When the sample is placed on the Balance, the Sensor quickly collects weight data, and the internal processor calculates Density, Baume or concentration in real time according to preset parameters. The results are displayed directly on the LCD screen.
Applications
Density measurement, Baume measurement, concentration analysis
Standards
External calibrating function
Steps
1. Adjust the level of the instrument through the front horizontal bubble
2. Turn on the power and wait for the system to initialize
3. Density upper and lower limits and specific gravity parameters as needed
4. Place the test sample for weighing
5. Read Density, Baume or concentration results displayed on the LCD screen
6. Optional connection to RS232 interface to transfer data to PC application
Notice
• Make sure the instrument is placed horizontally before use
• Operating Ambient Temperature should be kept within the range of 10 ° C-30 ° C
Periodic external calibration to ensure measurement accuracy
• Avoid use in humid or strong electromagnetic interference environments
• Handle with care during transportation and storage to prevent collisions
• Please use a dry soft cloth when cleaning to avoid liquids entering the inside of the instrument