Dual beam of light Metering system, stray light as low as ≤ 0.03% T, noise level ≤ 0.0004 Abs/h, with automatic Illuminant switching and Light spectrum data processing functions, easy and reliable operation.
Category : Spectrophotometer
Brand : Yoke
SKU : NB007229
Service :The delivery and service By NBCLab.Com
The YOKE UV1900 spectrophotometer is a high-performance analytical instrument with a dual beam of light Optical inspection system. Its wavelength range is 190~ 1100nm and the Light spectrum bandwidth is 2nm. The key components of the instrument are imported components, combined with unique Optical inspection and circuit design, to ensure low stray light, high photometric accuracy and excellent stability. It is suitable for a variety of Light spectrum analysis and Basis Weight determination.
1. Imported key components and unique Optical inspection system design, with excellent Optical Properties, low stray light and high photometry accuracy and stability. 2. Professional dual beam of light metering system and circuit measurement and control system, high reliability, low noise. 3. Illuminant (neon lamp and tungsten lamp) unique installation, support automatic switching and automatic positioning, easy operation, maintenance and replacement, safe. 4. Equipped with 320 * 240 point array highlight 6 inch LCD display, can directly display the scan map, the interface is simple and easy to use. 5. The software is powerful and supports automatic Light spectrum scanning, multi-wavelength measurement, kinetic measurement, Linear dispersion fitting, Derivative spectrum and map data access and printing. 6. Develop friendly software based on the Windows platform to facilitate data storage, output, and office applications. 7. Adopt 24-bit High Accuracy A/D conversion and ARM system, built-in Chinese and English dual operating system, large data storage capacity, support USB interface data transmission.
The instrument adopts a dual-beam of light Optical inspection system. After the composite light emitted by the Illuminant is split by the monochromator, monochromatic light is formed. The monochromatic light is divided into the sample beam of light and the reference beam of light, which pass through the sample cell and the reference cell respectively. The Detector (imported silicon photodiode) receives and compares the intensity signals of the two beams. After 24-bit high-speed High Accuracy A/D conversion and ARM system processing, the light transmitter (T), Absorbance (A), concentration (C) or energy (E) values of the sample are finally calculated, and the spectrum or data are displayed on the LCD screen.
Biochemical analysis, drug testing, environment monitoring, food inspection, chemical research, quality control
The data did not mention specific compliance criteria
Turn on the power supply (AC 220V/50Hz or AC 110V/60Hz) and start the instrument. 2. Instrument self-test, Illuminant automatically switches and locates to the best position. 3. Set the measurement parameters (such as wavelength, working mode T/A/C/E) through the film button or software interface. 4. Put the reference solution and the sample to be tested into the Cuvette and place them in the sample chamber. 5. Perform measurement operations (such as automatic scanning, multi-wavelength measurement or kinetic measurement). 6. View the map or data on the LCD, and perform Linear dispersion fitting, derivative analysis and other processing. 7. Save data through the USB interface or built-in storage, and connect the printer to output results.
• Make sure to use the correct Power frequency (AC 220V/50Hz or AC 110V/60Hz). • Operation and Maintenance When replacing the Illuminant, follow the instrument design to ensure safety. • Keep the Cuvette clean to avoid fingerprints or stains affecting measurement accuracy. • The instrument should be placed in a stable, no strong vibration, avoid direct sunlight environment. • Regularly calibrate and maintain instruments to ensure stable performance. When storing and transferring data, ensure that the USB interface connection is stable.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.