Using platinum plate and platinum ring two test methods, automatic measurement to avoid human error, measurement range 0~ 600mN/m, with automatic temperature compensation and accuracy correction function, suitable for real-time monitoring of surface tension changes in the sample.
Category : Surface Tensiometer
Brand : FangRui
SKU : NB008782
Service :The delivery and service By NBCLab.Com
The FANGRUI QBZY-1 interfacial tension instrument is a professional-grade interface chemical analysis instrument, specially designed to meet the user's needs for High Accuracy R & D and quality control in the interface chemical testing process. It analyzes the surface tension of liquids to study their physical performance in solubility, wettability, foaming, etc. It is the basic means of quality control in the industrialization process. The instrument has been awarded a national patent (patent number: 2011200652242).
1. Both platinum plate and platinum ring test methods are used (platinum ring method needs to be purchased separately). 2. Automatic measurement, platinum plate method test, the display value is the surface tension value. 3. When using the platinum ring method, the display value automatically locks the maximum force value, and the surface tension value can be calculated by the calculation software. 4. Fully automatic measurement to avoid human error. 5. Full scale automatic correction, accurate and reliable data, excellent repeability. 6. One key to clear zero, zero stable no drift. 7. Adopt professional lifting platform drive technology, without vibration or noise. 8. Reasonable structure, can work independently, without external computer, can also be equipped with computer for data processing. 9. The platinum plate method can measure the liquid surface tension in real time, and is suitable for the measurement of surface tension with time. 10. The platinum plate method can automatically test the surface tension of medium and high viscosity liquids. 11. Both test methods can measure the interfacial tension between dissimilar mixed liquids (such as the oil/water interface). 12. The data processing software can automatically collect and test Linear dispersion, compare and calculate Linear dispersion. 13. With accuracy correction function, calibrate with secondary distillation water and pure ethanol as standards. 14. Equipped with automatic temperature compensation function, the test values at different temperatures are uniformly summarized to the value at 20 ° C. 15. Comes with a variety of temperature control options to meet different test requirements.
The instrument adopts two test methods. Platinum plate method: When the platinum plate is immersed in the measured liquid, it is subjected to surface tension, and the instrument equilibrate sensor measures its immersion depth and converts it into surface tension value. The specific steps are to immerse the platinum plate, sense the equilibrate value, convert and display. Platinum ring method (du Nouy method): After immersing the platinum ring in the liquid, it slowly raises, and senses the maximum force value when the ring and the liquid surface are not separated. This value can be converted into surface tension value by calculation, and its accuracy is affected by the viscosity of the liquid.
Ink, inks, paints industry, printing industry, film industry, cleaning agent industry, auxiliary agent industry, cosmetics industry, Eletroplating industry, pesticide industry, nanofiber and powder research, petroleum industry, Spinning & weaving industry, food industry, power industry
1. Prepare instruments and samples to ensure level. 2. Select the test method (platinum plate method or platinum ring method). 3. Immerse the test part (platinum plate or platinum ring) in the liquid. 4. The instrument automatically measures and displays or records the relevant values. 5. Read the results directly by the instrument (platinum plate method) or use software to calculate the surface tension value (platinum ring method).
• The platinum ring needs to be purchased separately. • Ensure the level of the instrument before use. • Select the appropriate test method according to the sample characteristics (e.g. viscosity, volatility). • When making accurate measurements, it is recommended to use accuracy correction and temperature compensation functions. • Optional computer and data processing software for more detailed analysis Linear dispersion and data comparison. • When measuring medium and high viscosity samples or requiring temperature control, appropriate accessories should be selected. • Follow the instrument instructions when operating to avoid damage to precision components (e.g. platinum plates/rings).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.