| Product Name | Bante Bante901P-UK Portable Multi-ParaMeter water quality measurement instrument | HANNA HI8424 Acidity Meter |
| Product Price | $556.00 | $706.00 |
| Details | Details | |
| Model comparison | ||
| Type | Multiparameter | Multiparameter |
| Style | Portable | Portable |
| Detection Principle | Electrode Conductivity | Electrode |
| Measurement parameters | pH EC TDS ORP Temperature | pH ORP Temperature |
| Range | Wide Range | Wide Range |
| Accuracy | ±1%FS | ±0.5%FS |
| Resolution | 1 | 1 |
| Data Output | USB | |
| IP Rating | IP57 | |
| Parameter comparison | ||
| Measurement Range of pH | -2.000~20.000pH | |
| Measurement accuracy of pH | ±0.002pH | |
| pH resolution | 0.1, 0.01, 0.001 pH, optional | |
| pH calibrating point | 1 to 5 points | |
| pH calibrating solution | USA, NIST, DIN, Custom | |
| pH temperature compensation Range | 0~100℃, 32~212℉ | Automatic or manual temperature compensation in the Range of -20.0 - 120.0 ° C/-4.0 - 248.0 ° F (without temperature sensor) |
| pH temperature compensation | Manual or automatic | |
| ORP Measurement Range | -1999.9~1999.9mV | ±699.9mV;±1999mV |
| mV Measurement accuracy | ±0.2mV | |
| mV resolution | 0.1, 1mV, optional | |
| Measurement Range of conductivity | 0~ 20mS/cm (max 200mS/cm) | |
| Measurement accuracy of conductivity | ±0.5% F.S | |
| Conductivity resolution | 0.001, 0.01, 0.1, 1 | |
| Conductivity calibrating point | 1 to 5 points | |
| Conductivity calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | |
| Conductivity temperature compensation Range | 0~100℃, 32~212℉ | |
| Conductivity temperature compensation | Manual or automatic | |
| Conductivity temperature compensation coefficient | 0.0~10.0%/℃ | |
| Conductivity temperature compensation mode | Linear or pure water | |
| Conductivity detector cell constant | K = 0.1, 1, 10, custom | |
| Standardized temperature | 20℃, 25 ℃, optional | |
| TDS Measurement Range | 0~ 10ppt (max 200ppt) | |
| TDS Measurement accuracy | ±1% F.S | |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) | |
| Measurement Range | 0~105℃, 32~221℉ | |
| Measurement accuracy | ±0.5℃ | ±0.4℃/±0.8℉ |
| Temperature resolution | 0.1℃ | 0.1℃/0.1℉ |
| Temperature calibrated mode | 1 point | |
| Temperature unit | ° C, ° F, optional | |
| data lock | Manual or automatic end point locking | |
| Calibrated reminder | 1 to 31 days or closed | |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) | |
| One-click reset function | contain | |
| Data storage | 500 sets | |
| communication output | USB | |
| connector | BNC, 6-pin MINI connector | |
| Power supply Type | 3 AA batteries | |
| Battery life | Approximately 150 hours (when the LCD backlight is turned off) | 9V high-performance battery, 150 hours of continuous operation |
| Dimension | 170 (L) * 85 (W) * 30 (H) mm | |
| Instrument weight | 300g | |
| Optional Accessories | P11 Type pH Electrode, P11-LiCl Type pH Electrode, P11-HA Type pH Electrode, P11-NA Type pH Electrode, P 12 Type pH Electrode, P13 Type pH Electrode, P15 Type pH Electrode, P16 Type pH Electrode, P 18 Type pH Electrode, P19 Type pH Electrode, P21 Type pH Electrode, P22 Type pH Electrode, 501 Type ORP Electrode, 502 Type ORP Electrode, CON - 0.1 Type Conductivity detector Electrode, CON - 1 Type Conductivity detector Electrode, Con-10 Type Conductivity detector Electrode, TP - 10K temperature probe, Conductivity detector standard solution, pH standard buffer Reagent (USA Standard), pH Standard Buffer Reagent (NIST Standard) | |
| Packaging Dimensions | 340 (L) * 290 (W) * 80 (H) mm | |
| Encasement weight | 1.5kg | |