![]() |
![]() |
|
| Product Name | 3NH YS6010 Benchtop ColoriMeter | 3NH TS8216(Φ0.3mm) Benchtop ColoriMeter |
| Product Price | $9562.00 | In coming |
| Details | Details | |
| Model comparison | ||
| Sample type | Plane Powder Liquid | Plane Liquid |
| Measurement aperture | Φ4mm Φ8mm Miscellaneous | Miscellaneous |
| Measurement Geometry | D/8 D/0 | D/8 D/0 |
| Color difference formula | ΔE*ab ΔE*uv ΔE*94 ΔE*00 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) | ΔE*ab ΔE*uv ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) |
| Parameter comparison | ||
| Optical inspection structure | Reflection: D/8 (diffuse illumination, 8 ° direction reception); Transmission: D/0 (diffuse illumination, 0 ° direction reception) | Reflection: D/8 (diffuse illumination, 8 ° direction reception); Transmission: D/0 (diffuse illumination, 0 ° direction reception) |
| integrating sphere diameter | Φ154mm | Φ154mm |
| spectroscopy | Concave grating | Concave grating |
| Sensor | 256 pixel dual array CMOS image sensor | 256 pixel dual array CMOS image sensor |
| Field of view | 2°/10° | 2°/10° |
| Illuminant | 360~ 780Nm Combined LED Illuminant, 400nm Cut-off Illuminant | 360~ 780Nm Combination LED Illuminant, 400nm Cut-off Illuminant, 420nm Cut-off Illuminant |
| Illuminant life | More than 3 million measurements in 5 years | More than 3 million measurements in 5 years |
| UV Illuminant | Include UV/Exclude UV measurement | Includes UV/UV exclusion measurement (Illuminant) |
| Observational Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
| Wavelength range | 360~780nm | 360~780nm |
| wavelength interval | 10nm | 10nm |
| Bandwidth | 10nm | 5nm |
| Measurement caliber | Reflection: φ 30mm/φ 25.4mm, φ 10mm/φ 8mm, φ 6mm/φ 4mm; Transmission: φ 30mm/φ 25.4mm | Reflection: φ 0.3mm; Transmission: φ 4mm |
| Repeatability of chromatic value | φ 25.4mm/SCI, Delta E * ab within 0.02 (after correction, the average value of 30 whiteboard measurements at intervals of 5s) | φ 1mm/SCI, Delta E * ab within 0.15 (after instrument preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) |
| Spectroscopic reflectance Repeatability | φ 25.4mm/SCI, Standard Deviation within 0.05% (400~ 700nm: within 0.04%) | φ 1mm/SCI, Standard Deviation within 0.08% |
| Inter-instrument Agreement | φ 25.4mm/SCI, Delta E * ab within 0.15 (BCRA series ⅱ 12 color plate measurement average) | φ 1mm/SCI, Delta E * ab within 0.25 (BCRA series ⅱ 12 color plate measurement average) |
| Measurement time | About 2.4s (about 5s for simultaneous SCI/SCE testing) | About 2.4s (about 5s for simultaneous SCI/SCE testing) |
| Reflectance measurement range | 0~200% | 0~200% |
| Measurement mode | Reflection SCI/SCE, Transmission SCI/SCE | Reflection SCI/SCE, Transmission SCI/SCE |
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
| Whiteness/Yellowness/Blackness | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),TI(ASTM E313,CIE/ISO) | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) |
| Tint/Metamerism | Metamerism index Mt | Metamerism index Mt |
| Colour fastness/force/coverage | Dip colour fastness, discoloration fastness, force, coverage | Dip colour fastness, discoloration fastness, force, coverage |
| Glossiness/shade | 8 ° Glossiness, 555 shade classification | 555 shades, 8 ° Glossiness |
| Liquid/Transmission Special | Transmission: d: 0 ° structure (diffuse illumination, 0 ° direction reception), compliant with ISO, CIE, ASTM and DIN standards | APHA/Hazen/Pt-Co (platinum cobalt index), Gardner index, Saybolt (Seibert index), ASTM D1500 color code, Chinese Pharmacopoeia color code |
| Haze/Transmittance | Spectral Transmittance φ 25.4mm/SCI, Standard Deviation within 0.05% (400~ 700nm: within 0.04%) | Haze (ASTM D1003) |
| Software support | The PC-side software has powerful expansion functions | SQCX Quality Management Software |
| Data storage | 2000 master standards, 20,000 samples (SCI/SCE counts as one data) | 5000 master standards, 40,000 samples (SCI/SCE counts as one data) |
| Interface | USB, print serial port | USB, Bluetooth ® 5.0, print serial port |
| display screen | TFT True Color 7inch, Capacitive Touchscreen | TFT True Color 7inch, Capacitive Touchscreen |
| display content | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias |
| Operating language | Simplified Chinese, Traditional Chinese, English | Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish) |
| Operating temperature | 0~40℃(32~104°F) | 0~40℃(32~104°F) |
| Storage temperature | -20~50℃(-4~122°F) | -20~50℃(-4~122°F) |
| Power supply method | DC 24V, 2A Power Adapter | DC 24V, 3A Power Adapter |
| Dimension | 370*300*200mm | L * W * H = 370 * 300 * 200mm |
| Net weight | About 9.6kg | About 9.6kg |
| Optional accessories | Micro printer, transmission test fixture assembly, inspection green board | Microprinters, instrument inverted test fixtures, culture dishes |
| Special features | Bluetooth 2.1; aperture automatic identification; temperature monitoring and compensation; built-in camera precision positioning; built-in 400nm cutoff/420nm cutoff/460nm (limited to xenon arc version) | Micropore aperture; Dual array CMOS; Combined Full Light spectrum LED Illuminant; Industrial high definition Touchscreen; Measurement verification report; Light mode SCI/SCE |