| Product Name | Bante M852 6-In-1 STIP-scan | Bante Bante90 Portable Intelligent Multi-ParaMeter |
| Product Price | In coming | $922.00 |
| Details | Details | |
| Model comparison | ||
| Type | Multiparameter | Multiparameter |
| Style | Portable | Portable |
| Detection Principle | Electrode Conductivity DO Method | Electrode Conductivity DO Method |
| Measurement parameters | pH DO EC TDS Salinity Temperature | pH DO EC TDS ORP Salinity Temperature |
| Range | Wide Range | Wide Range |
| Accuracy | ±5%FS | ±2%FS |
| Resolution | 1 | 1 |
| Data Output | USB Bluetooth | |
| IP Rating | ||
| Parameter comparison | ||
| PH Measurement Range | -1.00~15.00pH | |
| PH Display resolution | 0.01pH | |
| PH Measurement accuracy | ±0.01pH | |
| PH calibrating point | 1 to 3 points | |
| PH buffering options | USA (pH4.01/7.00/10.01), NIST (pH4.01/6.86/9.18) | |
| EC Measurement Range | 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm | |
| EC resolution | 0.01, 0.1, 1 | |
| EC Measurement accuracy | ±1% F.S. | |
| EC calibrating point | 1~ 3 points | |
| EC uses calibrating fluid | 84µS, 1413µS, 12.88mS | |
| TDS Measurement Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt | 0~200.0g/L |
| TDS Display resolution | 0.01, 0.1, 1 | |
| TDS Measurement accuracy | ±1% F.S. | ±1%F.S. |
| TDS conversion factor | 0.1 to 1.0 (default 0.5) | 0.01 to 1 (default 0.5) |
| Measurement Range of salinity | 0~10.00ppt | |
| Salinity resolution | 0.01ppt | |
| Measurement accuracy of salinity | ±1% F.S. | ±1%F.S. |
| DO Measurement Range | 0.0~20.0mg/L | 0.00~20.00mg/L |
| DOS resolution | 0.1mg/L | |
| DO Measurement accuracy | ±0.5mg/L | ±0.2mg/L |
| DO% Measurement Range | 0.0~200.0% | 0.0~200.0% |
| DO% resolution | 0.001 | |
| DO% Measurement accuracy | ±2.0% | ±2.0% |
| DO calibrated point | 1 or 2 points | |
| DO atmospheric pressure compensation Range | 450~ 850mmHg, manual | |
| DO salinity compensation Range | 0~ 35G/L, manual | |
| Measurement Range | 0~60℃/32~140°F | |
| Temperature resolution | 0.1℃/0.1°F | |
| Measurement accuracy | ±1℃/±1.8°F | |
| Temperature offset calibrated | 1 point, Measured value +/- 10 ℃ | |
| PH temperature compensation Range | 0~ 60 ° C/32~ 140 ° F, Automatic | |
| EC temperature compensation Range | 0~ 60 ° C/32~ 140 ° F, Automatic | |
| DO temperature compensation Range | 0~ 40 ° C/32~ 104 ° F, Automatic | |
| EC temperature compensation coefficient | 2%/℃, linear | |
| EC reference temperature | 25℃ | |
| EC Conductivity detector cell constant | K=1 | |
| data lock | Manual or automatic | |
| Automatic shutdown | After 40 minutes of no button operation | |
| power supply | 3 LR44 batteries | |