| Product Name | LeiCi DZS-706F Multi-ParaMeter Analyzer | Yoke P16 Touchscreen Benchtop 3 in 1 |
| Product Price | $1142.00 | In coming |
| Details | Details | |
| Model comparison | ||
| Type | Multiparameter | Multiparameter |
| Style | desktop | desktop |
| Detection Principle | Electrode Conductivity DO Method | DO Method |
| Measurement parameters | pH DO EC TDS Salinity Temperature | pH DO EC TDS Salinity Temperature Others |
| Range | Wide Range | Wide Range |
| Accuracy | ±1%FS | ±1%FS |
| Resolution | 0.1 | 1 |
| Data Output | RS232 USB | USB Bluetooth |
| IP Rating | IP54 | IP54 |
| Parameter comparison | ||
| pH/pX level | 0.01 level | |
| Conductivity level | Level 1.0 | |
| mV Measurement Range | (-2000.0~2000.0)mV | -2000mV ~ 0 ~ 2000mV |
| mV resolution | 0.1mV | 1 mV |
| mV Electronic Unit Indication Error | +/- 0.1% or +/- 0.3mV | |
| mV Electronic Unit Repeatability | 0.5mV | |
| mV Electronic Unit Input Impedance | ≥1*10¹²Ω | |
| Measurement Range of pH | (-2.00~20.00)pH | -1.99 ~ 19.99 pH |
| pH resolution | 0.01pH | 0.1/0.01 pH |
| pH Electronic Unit Indication Error | ±0.01pH | |
| Repeatability of pH electron unit | 0.005pH | |
| pH Instrument Indication Error | ±0.02pH | |
| pH Instrument Repeatability | 0.01pH | |
| pX Measurement Range | (-2.00~20.00)pX | |
| pX resolution | 0.01pX | |
| pX Electronic Unit Indication Error | ±0.01pX | |
| pX Electronic Unit Repeatability | 0.005pX | |
| pX Instrument Indication Error | ±0.02pX | |
| pX Instrument Repeatability | 0.01pX | |
| Ion concentration Range | (0~ 19990), optional units mol/L, mmol/L, g/L, mg/L, μg/L | |
| Ion minimum resolution | 4 significant digits | |
| Ion Electronic Unit Indication Error | ±0.5% | |
| Ion conductivity Range | 0.000μS/cm~1000mS/cm | |
| Ion conductivity minimum resolution | 0.001 μS/cm, automatic switching | |
| Ion conductivity electronic unit reference error | ±1.0%(FS) | |
| Repeatability of ion conductivity electronic unit | 0.33%(FS) | |
| Ion conductivity instrument reference error | ±1.50%(FS) | |
| Repeatability of ion conductivity instrument | 0.50%(FS) | |
| resistivity Range | 5.00Ω·cm~20.00MΩ·cm | |
| Resistivity minimum resolution | 0.01Ω · cm, automatic switching | |
| Resistivity Electronic Unit Reference Error | ±1.0%(FS) | |
| TDS Measurement Range | 0.00mg/L~300g/L | 0 ~ 100 g/L |
| TDS resolution | 0.01Mg/L, automatic switching | |
| TDS electronic unit reference error | ±1.0%(FS) | |
| Measurement Range of salinity | (0.00~8.00)% | 0 ~ 100 ppt |
| Salinity minimum resolution | 0.01% | |
| Salinity electronic unit reference error | ±0.2% | |
| Reference error of salinity instrument | ±0.4% | |
| DO Measurement Range | (0.00~20.00)mg/L | 0 ~ 20.00 mg/L(ppm),0 ~ 200.0 % |
| DOS resolution | 0.01mg/L | 0.1/0.01 mg/L(ppm),1/0.1 % |
| DO Electronic Unit Indication Error | ±0.10mg/L | |
| DO zero value error | ≤0.1mg/L | |
| DO Response Time | ≤ 45s (90% Response at 20.0 ° C) | |
| DOS Indication Error | ±0.30mg/L | |
| Saturation Range | (0.0~200.0)% | |
| Saturation minimum resolution | 0.1% | |
| Saturation Electronic Unit Indication Error | ±2.0% | |
| Saturation Instrument Indication Error | ±10.0% | |
| Temperature Range | (-5.0~110.0)℃ | |
| Temperature resolution | 0.1℃ | 0.1 ℃ |
| Temperature Electronic Unit Indication Error | ±0.2℃ | |
| Temperature Instrument Indication Error | +/- 0.4 ° C (0.0 ° C -60.0℃) +/- 1.0 ° C (Miscellaneous Range) | |
| Operating Environment | Ambient Temperature: (0~ 40) ℃ relative humidity: not more than 85% | |
| Size | 242*195*68mm | |
| weight | About 0.9kg | 880 g |
| Power supply | Power Adapter (Input: AC 100~ 240V Output: DC 9V) | |