Product Name 3NH YL4660 Non-contact ColoriMeter 3NH YL4668 Non-contact ColoriMeter
Product Price $7464.00 $8109.00
Details Details
Model comparison
Sample type Plane Powder Paste Liquid Plane Powder Paste Liquid
Measurement aperture Miscellaneous Miscellaneous
Measurement Geometry 45°/0 D/8
Color difference formula ΔE*ab ΔE*uv ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) ΔE*ab ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter)
Parameter comparison
Optical inspection structure 45/0 (45 ring uniform illumination 0 ° reception) D/8 (diffuse illumination, 8 ° direction reception, SCI includes specular reflection)
spectroscopy Concave grating spectroscopy Concave grating spectroscopy
Sensor 256 pixel dual array CMOS image sensor 256 pixel dual array CMOS image sensor
Field of view 2°/10° 2°/10°
Illuminant Light spectrum LED Illuminant Light spectrum LED Illuminant, UV Illuminant
Illuminant life More than 3 million measurements in 5 years More than 3 million measurements in 5 years
UV Illuminant Yes. contain
Observational Illuminant D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)
Wavelength range 400~700nm 400~700nm
wavelength interval 10nm 10Nm output
Measurement caliber Φ20mm φ 20mm (customizable φ 10mm)
Repeatability of chromatic value Delta E * ab within 0.03 Delta E * ab within 0.03 (after preheating, the average value of 30 whiteboard measurements at intervals of 5s)
Spectroscopic reflectance Repeatability Standard Deviation Within 0.08% Standard Deviation within 0.1% (optimal test mode, 1.5 seconds for a single measurement)
Inter-instrument Agreement Delta E * ab within 0.2 Delta E * ab within 0.2 (BCRA series ⅱ 12 swatches measurement average)
Measurement time Fast mode about 1.0s (0.2~ 1.5s adjustable) The fastest is 0.2 seconds.
Reflectance measurement range 0~200% 0~200%
Measurement mode Single measurement, average measurement (2~ 99 times) Single measurement, average measurement (2~ 99 times)
Color space CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color difference formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter),DINΔE99
Whiteness/Yellowness/Blackness WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313)
Tint/Metamerism Metamerism Index MI Metamerism Index MI
Colour fastness/force/coverage Dip colour fastness, discoloration fastness, force, coverage Dip colour fastness, discoloration fastness, force, coverage
Software support The PC-side software has powerful expansion functions Software customization capabilities (additional customization needs to be evaluated)
Data storage 40,000 sample mode + quality control mode; 10,000 continuous statistical mode 18,000 sample mode + quality control mode, 30,000 consecutive statistics, no more than 48,000 in total
Interface USB/RS-232, Bluetooth 5.0 USB, Bluetooth ® 5.0
display screen TFT True Color 7inch, Capacitive Touchscreen TFT True Color 7inch, Capacitive Touchscreen
display content Light spectrum graph/data, sample chromatic value, color difference value/graph, chromaticity graph, Color simulation, pass/fail results, display tolerance can be set Light spectrum graph/data, sample chromatic value, color difference value/graph, Color simulation, pass/fail results, tolerance can be set
Operating language Simplified Chinese, Traditional Chinese, English Simplified Chinese, Traditional Chinese, English
Operating temperature 0~40℃ 0~40℃
Allowable relative humidity 0~ 85% RH (no condensation) 0~ 85% RH (no condensation)
Storage temperature -20~50℃ -20~50℃
Storage Humidity 0~ 85% RH (no condensation) 0~ 85% RH (no condensation)
Power supply method DC 24V, 3A Power Adapter DC 24V, 3A Power Adapter
Dimension 330*250*370mm 200 * 200 * 160Mm (Probe)
Net weight About 10Kg Approximately 3Kg (Probe only)
Special features Non-contact measurement, test Probe and test sample non-contact test; built-in camera viewfinder positioning; sample height can be stored; manual/automatic distance adjustment Non-contact measurement, can be placed in any position of automated production online, support fluorescent sample measurement, camera positioning, distance adjustment method according to the actual sample fixed height