Product Name Apkjgroup 2AP-CJ-100A Thermal Shock Test Chamber AISRY NBC-80B Thermal Shock Test Chamber
Product Price In coming $15403.00
Details Details
Model comparison
Structure Type Two-zone Two-zone
Sample Movement Movable (Basket) Movable (Basket)
Shock Temp Range -40℃~+150℃ -40℃~+150℃
Hot Zone Range +60℃~+180℃
Cold Zone Range -10℃~-40℃ -10℃~-55℃
volume 51-100L 51-100L
Recovery Time ≤5min
Transfer Time ≤10s ≤10s
Cooling Method Air-cooled Air-cooled
Sample Load Capacity 21-50kg 11-20kg
Defrost Function Automatic Defrost
Parameter comparison
Temperature Range -40 ℃~ + 150 ℃ (Air-Cooled)60 ℃~ 150 ℃ (arbitrarily adjustable)RT~+195℃RT~-55℃
Temperature Fluctuation ±0.5℃ ±2℃
Temperature deviation ±2.0℃
Volume 100L 80L
Inner box Size 500*500*400mm (W*H*D)
External dimensions 1500*1950*1850mm (W*H*D)
weight About 750kg
Low Temperature Impact Range -10 ℃~ -40 ℃ (optional)
Temperature Range -40 ℃~ + 150 ℃ (Air-Cooled)60 ℃~ 150 ℃ (arbitrarily adjustable)RT~+195℃RT~-55℃
Temperature Range -40 ℃~ + 150 ℃ (Air-Cooled)60 ℃~ 150 ℃ (arbitrarily adjustable)RT~+195℃RT~-55℃
Heating time + 50 ℃ → + 195 ℃ ≤ 40min (high greenhouse runs separately)
Temperature Range -40 ℃~ + 150 ℃ (Air-Cooled)60 ℃~ 150 ℃ (arbitrarily adjustable)RT~+195℃RT~-55℃
cooling time + 20 ℃ → -55 ℃ ≤ about 90min (low greenhouse runs alone)
temperature recovery time ≤ 5min; conversion time ≤ 10s (basket movement ≤ 3s)
Impact exposure time ≥30min
Test method Two Box Mobile Thermal Shock, Air Pressure Driven Basket Moves Up and Down
Outer wall material Optional SUS304 stainless steel or fine powder paint
Inner box material SUS304 stainless steel SUS #304 Thickened heat-resistant and cold-resistant stainless steel plate, first-class light panel
Box insulation material Rigid polyurethane foam
Air conditioning channel Fan, heater, evaporator, damper, temperature sensor
Specimen shelf 1 set of two layers (with 4 hooks), bearing 25kg
Lead Hole (Optional) 1, with a 50mm round hole on the left side of the box.
Adjusting feet and adjusting wheels 4 adjustment feet and 4 adjustment wheels.
Test chamber door Single opening, left hinge, right handle
circulating fan High temperature/ambient temperature exposure: 3φ 400W centrifugal; low temperature exposure: 3φ 400W centrifugal
Control Panel Controller display, fault light, timer, USB/R232, over-temperature protection, main power switch
Machinery room Refrigeration unit, drainage device, exhaust fan
Distribution control cabinet Leakage circuit breaker, controller, switchboard, cooling fan, circulating fan motor
heater Nickel chromium alloy heating wire Type
Control mode of heater Touchless point isoperiodic pulse width modulation, SSR (solid state relay)
Power cord holes and drainage holes Located on the back of the box
Refrigeration compressor Original imported France Taikang or Japan Hitachi fully enclosed low noise rotary compressor Adopt imported compressor unit
evaporator finned tube heat exchanger
condenser shell and tube heat exchanger
Throttle device Thermal expansion valve, capillary tubing
Evaporative condenser Stainless steel brazed plate heat exchanger
Control mode of refrigerator PLC automatically adjusts operating conditions, return air chill down, energy regulation, condensation pressure regulation
refrigerant R404a/R23 (ozone depletion index 0)
controller Programmable Touchscreen Controller, can be arbitrarily set high and low temperature Impact temperature point
display LCD liquid crystal display
operation mode procedural approach Program running, constant running
setting method All Chinese LCD display (switchable English), LCD touch panel
program capacity Up to 120 sets of procedures, each set of 3 zones and 3 segments, each segment can reach 999 times, and the time is 0 to 999 hours and 59 minutes
Display resolution Temperature: 0.1 ℃; Time: 0.1 min
electrical input Thermocouple
Storage device USB and R232 communication interface
Control mode Anti-integral saturation PID, fuzzy algorithm, BTC equilibrating temperature control
Linear dispersion recording function Real-time display of graphics during program execution Linear dispersion
subsidiary function power-off memory, automatic renewal, time adjustment, appointment start and stop, screen lock
Test environmental conditions Ambient Temperature + 25~ + 30 ℃, relative humidity ≤ 85%, air pressure 86kPa~ 106kPa
environmental conditions Ambient Temperature 5 ℃~ 35 ℃, relative humidity ≤ 85%, pressure 86kPa~ 106kPa
Air source pressure 5~7 kg/cm²
Air source connecting pipe diameter Φ8mm
Flow rate of gas source 0.1m³/min
Maximum current consumption Current 18A, Power about 12.0Kw (Voltage Range +/- 10%)
Requirements for storage environment Ambient Temperature 0 ℃~ + 45 ℃ when not working, lower than 0 ℃ needs to be drained and antifreeze