Small Low-Temperature Water Tank

The small low-temperature bath cools the liquid inside the tank and maintains a constant low temperature through compressor refrigeration or thermoelectric cooling. It is used in scenarios such as laboratory sample cooling, reactor temperature control, and low-temperature material testing, providing a stable low-temperature environment for experiments.
Selection
When selecting, consider that the temperature range must cover experimental requirements, temperature control accuracy must meet sample needs, tank volume should match container sizes, the cooling method should be chosen based on energy consumption and noise levels, while also paying attention to tank opening dimensions for ease of operation, and material corrosion resistance should be suitable for the working liquid.

Terms

Standards

Instruments

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

Temperature control range -10~ 95 ℃, accuracy up to +/- 0.05 ℃, equipped with 6L/min circulating pump to ensure uniform temperature, Tank volume 7.5L to meet the needs of multi-sample testing.

$ 1429.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Temperature range -20~ 95 ℃, temperature accuracy +/- 0.05 ℃, Tank volume 15L, equipped with 6L/min circulating pump to ensure uniform and stable temperature, suitable for a variety of experimental needs.

$ 1726.00

Temperature range -40~ 95 ℃, temperature accuracy +/- 0.1 ℃, Tank volume 15L, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 2936.00

Temperature range -5~ 95 ℃, accuracy +/- 0.05 ℃, Tank volume 15L, pump flow 6L/min, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 1505.00

Temperature range -20 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and anti-scaling, protect precision instruments in high temperature environment stable operation.

$ 1900.00

Temperature range -30 to 100 ℃, Tank volume 4.5 liters, imported Compressor and circulating pump to ensure stable operation, support multi-stage programmable control and internal and external circulation mode.

$ 1450.00

Temperature range -50~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with over-temperature low temperature sound and light alarm and liquid level protection, support multi-stage programmable control, circulating pump Flow rate 8L/min, to ensure the safe and stable operation of the sample.

$ 3028.00

Temperature range -10~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, low noise, fast cooling, with over-temperature alarm and liquid level protection function, support multi-stage programming and data processing interface.

$ 1756.00

Temperature range 10~ 99 ℃, temperature control accuracy +/- 1 ℃, stainless steel liner anti-corrosion, stepless speed motor low noise, support multi-stage programmable control to simplify the experimental process.

$ 2447.00

Temperature range -20~ 100 ℃, accuracy +/- 0.02 ℃, equipped with over-temperature alarm and liquid level protection function, using imported Compressor noise low cooling fast, support multi-stage programmable and data processing interface.

$ 1953.00

With +/- 0.1 ℃ temperature fluctuation and 0.1 ℃ resolution, built-in circulating water pump supports internal and external circulation, integrated over-temperature alarm and 9999 minutes timing function to ensure stable and efficient experiment.

$ 1434.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

With a wide temperature range of -40~ 100 ℃, temperature control accuracy +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection functions to ensure safe operation.

$ 1747.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.