Glass disc diaMeter 240mm, Rotation speed 75 +/- 5rpm, using microcomputer control to achieve reliable operation, compact structure for easy assembly and disassembly and paraMeter change.
Using microcomputer automatic control, the ink wiping speed is 15.5 +/- 1.0cm/min, the opening area of the ink coating platen is 20 +/- 0.4cm ², and the automatic adjustment range of paper pattern thickness is supported by 0.1~ 1.0mm. Test accuracy and operation convenience are ensured.
Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.
Using microcomputer drive technology and imported stepper motor, Speed range 0.3-60 rpm, viscosity measurement range 1-2000000mPa · s, with automatic scanning function to help select the right Rotor speed, ensure High Accuracy and Repeatability.
Using microcomputer drive technology, equipped with imported stepper motor, Speed range 6/12/30/60rpm, viscosity measurement range 1~ 100000mPa · s, with automatic scanning function, can automatically prompt the appropriate Rotor speed combination to ensure High Accuracy and Repeatability.
Microcomputer control to ensure accurate and stable measurement, Measurement range covering 0~ 199.9mS/cm, manual temperature compensation range of 10~ 50 ℃, equipped with standard calibrated seat for regular calibrated maintenance.
Microcomputer temperature control technology, temperature control accuracy of +/- 0.5 ℃, support up to 5 temperature point programming operation, metal module design to avoid sample contamination and easy to clean and disinfect.
Microcomputer thermostatic control system, Temperature Fluctuation +/- 0.05 ℃, display resolution 0.1 ℃, pump flow 8L/min, with break protection and over-temperature alarm function, support internal and external circulation.
Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.
Spreader 13 micron wet film thickness, application width up to 300mm, 304 stainless steel for durability and precise coating control.
Using microcomputer control and high-quality imported components, Repeatability ≤ 0.02, can measure the blue light 457nm diffuse reflection factor and fluorescence whiteness F value, the optical path design is simple and reasonable to ensure accurate and stable measurement.
With microcomputer programming control, can independently set the temperature Illumrination degree, light intensity 0~ 12000LX adjustable, Temperature Fluctuation +/- 0.5 ℃, support power-off memory and internal dehumidification function to ensure a stable environment.
Adjustable application width, with automatic Spreader function, easy to operate, Repeatability is good, suitable for a variety of samples of laboratory prepative.
Using microcomputer intelligent temperature control, Temperature Fluctuation +/- 0.5 ℃, equipped with hot air circulation system to ensure uniform temperature, support multi-stage programming and UV sterilization optional function.
Microcomputer thermostatic control system, Temperature Fluctuation +/- 0.05 ℃, display resolution 0.1 ° C, with breaking protection and over-temperature alarm function, pump flow 8L/min.