Physical and Chemical Melting Point Apparatus

A physical and chemical melting point apparatus measures the transition temperature of a substance from solid to liquid by heating the sample and monitoring its phase change process. It is used to detect the melting points of chemicals, pharmaceuticals, plastics, and other materials to confirm purity or identify substances. It is applied in chemical engineering, pharmaceuticals, and material analysis.
Selection
When selecting a physical and chemical melting point apparatus, consider the following: the temperature range should cover the melting point of the sample, the heating rate should be adjustable to meet different standards, the sample capacity should align with routine testing volumes, and the instrument should feature automatic melting point recognition to minimize human error, along with a user-friendly interface.

Terms

Standards

Instruments

It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.

$ 3172.00

With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.

$ 988.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.

$ 4414.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.

$ 2397.00

Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.

$ 654.00

Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.

$ 1521.00

Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.

$ 5754.00

With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.

$ 1501.00

Using photoelectric detection technology to automatically identify the initial and final melting points, equipped with Platinum Resistance Sensor to ensure +/- 0.5 ℃ accuracy, support eight linear heating rate and automatic storage function, no manual monitoring can complete the measurement.

$ 1116.00

Using photoelectric automatic detection technology, the temperature resolution reaches 0.1 ℃, the temperature control system applies PID regulation and PWM technology to improve the measurement accuracy and reliability, and supports automatic recording of initial melting and final melting results.

$ 1855.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.

$ 1526.00

Using 30fps high-resolution video and 720P camera to observe the sample melting process in real time, support 0.1-20 ℃/min heating rate adjustable and four capillary tubing simultaneous processing, in line with pharmacopoeia specifications.

$ 4269.00

With 0.2~ 5 ℃/min eight linear heating rate control, Temperature resolution of 0.1 ℃, Support Capillary Method and Cover Slip Method Measurement mode, Can observe 40X~ 100X zoom sample melting process.

$ 2244.00

Articles