Optical Electronic Balance

Optical electronic balances display weighing results through optical projection magnification and utilize the principle of electromagnetic force balance for weighing. They are used in laboratories to weigh samples and test raw material ratios in the coatings and inks industry.
Selection
When selecting, consider whether the weighing range and accuracy meet the sample requirements, pay attention to environmental adaptability such as shock and wind resistance, check calibration functions, confirm ease of operation and data output methods, and compare the prices and after-sales services of different brands.

Terms

Standards

Instruments

Using electromagnetic force equilibrated Electronic Balance and halogen radiation technology, moisture readability of 0.02%, Heating Temperature range RT + to 200 ℃, quickly complete the test in a few minutes, durable and functional.

$ 746.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for easy connection to external devices.

$ 656.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for easy data connection.

$ 425.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, adjustable weighing speed of fast, medium and slow, and equipped with RS-232 interface for data connection.

$ 637.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading in 2 seconds, Measurement speed, Sensitivity can be adjusted in gears, and equipped with RS-232 interface for data connection.

$ 1151.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for data output.

$ 485.00

Using diffuse transmission optical path design, optical density Measurement range 0.00-6 OD, light transmitance accuracy +/- 2%, can simultaneously measure light transmitance, absolute optical density, relative optical density and Dot area ratio.

$ 673.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 1203.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Sensor and microcomputer combination, weighing range 0~ 1000g, accuracy 0.1g, with Automatic calibration, automatic clearing, Zero tracking and fault display functions, support counting and RS232 serial port connection.

$ 164.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Using photoelectric detection and microcomputer servo system, high Sensitivity, minimum reading +/- 0.005 °, Repeatability ≤ 0.007 °, low optical rotation samples with measurable transmittance ≥ 10%, no reading error.

$ 1098.00

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
Multilayer functional films are constructed by layer-by-layer coating using a coating machine.
This article introduces a method for preparing multilayer functional films using a coating mechanism. By sequentially coating different materials layer by layer, it enables precise control over the thickness and structure of each layer, thereby adjusting the optical, electrical, and other properties of the films.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter detects the transparent scattering characteristics of optical coatings.
This article introduces how a haze meter detects the transparency and scattering characteristics of optical coatings. Optical coatings are used in fields such as displays and packaging, where their transparency and scattered light can affect product performance.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Coating Distinctness of Image (DOI) Meter Evaluates Surface Imaging Clarity
The Coating Distinctness of Image (DOI) meter is an optical instrument used for quantifying the imaging clarity of coating surfaces. It analyzes the reflection of standard patterns on the coating, measuring the ratio of specular reflection to diffuse reflection to obtain an objective DOI value.
Principle and Application of Whiteness Meter in Measuring Coating Whiteness
A whiteness meter quantifies the whiteness of paint samples by simulating human perception of white, measuring the diffuse reflectance of light—particularly in the blue wavelength range—and converting it into a numerical whiteness value. It employs standardized optical configurations and mathematical models, such as the Ganz formula, to assess the brightness and chromaticity of coatings.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.