Vertical Rocker

A vertical shaker drives the platform to perform vertical reciprocating motion through a motor, ensuring uniform mixing of samples in containers. It is used for dispersing and stirring coatings and inks, as well as homogenizing laboratory samples. It facilitates thorough contact between substances in dye dispersion and slurry preparation.
Selection
Select the platform size based on the sample container dimensions. Match the swing amplitude within the range of 5-50mm according to the sample viscosity. For routine mixing, choose a rotation speed of 60-300rpm. Use a stainless steel tabletop for corrosive environments, opt for a heating type for temperature control needs, and consider fixture compatibility for the fixation method.

Terms

Standards

Instruments

The fixture can fix the upper and lower ends of the butterfly specimen into a vertical shape, test the vertical compression strength, suitable for a variety of Corrugated Board types, Dimension 150 * 105 * 65mm, weight about 2Kg, easy to operate.

$ 596.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

The swirl/spin design is suitable for long-term use, with a three-dimensional roll tilt angle of 10 °, a maximum load of 5kg, a speed range of 10-70rpm, and can be operated in a low temperature Thermal Chamber.

$ 472.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Support forward and reverse rewinding and unwinding functions, with tension control and deviation correction functions, vertical mesh running speed 1mm/s to 1m/min, effective coating area 1500 * 600mm, to ensure that the mesh vertical stability without shaking.

$ 14274.00

Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.

$ 958.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.

$ 603.00

Vertical oscillation mode with 280rpm frequency, smooth operation and low noise, stainless steel spring universal fixture, can be adapted to a variety of test bottles, to meet a variety of mixing needs.

$ 356.00

Adopting crane bearing swirl/spin design, no abrasion and suitable for long-term operation; speed range 10-80rpm, maximum load 5kg; molded shell is acid and alkali resistant and easy to clean, can be used in the refrigerator.

$ 430.00

With vertical oscillation mode, Oscillation Frequency up to 280rpm, pendulum amplitude of 20mm, smooth operation and low noise, stepless speed regulation can be flexibly adjusted, stainless steel spring fixture is suitable for a variety of test bottles.

$ 393.00

Vertical double air duct vertical hot air circulation to ensure uniform temperature distribution, temperature control accuracy of +/- 1.0 ℃, equipped with large screen LCD display and independent temperature limit alarm system, support 1-9999 minutes timing function, effectively ensure the safe and stable operation of the experiment.

$ 3410.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Standard Operating Procedure for Packaging Drop Tester
The packaging drop tester is used to evaluate the impact resistance of transport packages during vertical drops. Before operation, it is necessary to check the safety of the equipment, calibrate the drop height, and prepare the test specimens according to standards.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Pull-off adhesion tester quantitatively measures bond strength.
The pull-off adhesion tester measures the bonding strength between coatings, linings, and substrates by applying a vertical tensile force.
Pull-off testing for interlayer adhesion of multilayer coating systems.
This article introduces the pull-off method for testing the interlayer adhesion of multilayer coating systems. The test involves vertically bonding a pull-off head to the coating surface and applying a pulling force until the coating separates, measuring the required force to evaluate adhesion strength.
Sag resistance and leveling in constructability evaluation
This article primarily discusses how to balance the two key properties of sag resistance and leveling during the application of materials such as coatings and adhesives. Sag resistance refers to the material's ability to resist sagging due to gravity on vertical surfaces, while leveling refers to the material's ability to automatically smooth out its surface after application.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
What are the differences between horizontal airflow and vertical airflow in a clean bench?
Purification workbenches primarily employ two types of air supply methods: horizontal and vertical. In horizontal air supply, the airflow is parallel to the work surface, while in vertical air supply, the airflow moves from top to bottom, forming a laminar barrier. The selection should be based on a comprehensive consideration of experimental needs, sample characteristics, and safety requirements.
The softness tester can show a data difference of up to 30% when measuring paper hand-feel samples taken from different directions.
This article mainly discusses that when testing the softness of paper, if samples are taken along different directions, such as the machine direction (longitudinal) and the cross direction (transverse), the measured data can vary significantly, sometimes by as much as 30%.