Temperature-Regulated Drying Oven

The temperature-controlled drying oven uses heating elements and a temperature controller to maintain a constant internal temperature, allowing the moisture in samples to evaporate. It is used in laboratories for drying samples, curing materials, and removing solvents. It is commonly found in production and inspection processes in the chemical, food, and pharmaceutical industries.
Selection
When selecting, consider the temperature range and uniformity, the corrosion resistance of the inner chamber material, the load capacity and quantity of the sample racks, the insulation performance of the cabinet, as well as the temperature control accuracy and safety protection features. Determine the volume and dimensions based on the characteristics of the samples, and choose the power specifications and exhaust interfaces according to the usage environment.

Terms

Standards

Instruments

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Temperature uniformity is improved by air circulation system, temperature control accuracy is +/- 0.5 ℃, Temperature resolution is 0.1 ℃, mirror stainless steel liner ensures durability and easy cleaning, suitable for a variety of drying applications.

$ 435.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, with forced warm air circulation to ensure uniform temperature, optional RS-485 interface to record temperature changes.

$ 971.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ to +/- 1 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner easy to clean.

$ 761.00

Mirror stainless steel liner is easy to clean, Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ or +/- 1 ℃, with forced warm air circulation and timing function to ensure uniform and stable temperature.

$ 470.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

With 24 independent temperature control studios, Temperature range RT +~ 50 ℃, air disturbance technology and three-stage purification system are used to avoid cross-contamination of samples and improve drying efficiency.

$ 3723.00

Microcomputer PID temperature controller to ensure accurate and reliable temperature control, Temperature Uniformity +/- 3%, hot air circulation system to improve Temperature uniformity, independent temperature limit alarm system to ensure experimental safety.

$ 438.00

Temperature uniformity with natural convection design, temperature control accuracy of +/- 0.5 ° C, volume of 70L, independent temperature limit alarm system and timing function for 9999 minutes, suitable for a variety of drying sterilizing applications.

$ 761.00

Ceramic fiber material, Temperature range RT + 20~ 400 ℃, liner size 450 × 450 × 450mm, with multi-stage programmable control, independent temperature limit alarm and fast and stable temperature control function, easy to clean and automatic operation.

$ 2052.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.