Thermal Imaging Infrared Device

Thermal imaging infrared instruments detect infrared radiation emitted from the surface of objects and convert it into temperature distribution images. They are used to detect abnormal surface temperatures of materials, monitor equipment operating conditions, and locate thermal energy distribution. In the industrial field, they are applied for fault diagnosis, energy consumption analysis, and quality monitoring.
Selection
When selecting, consider the detection temperature range and accuracy, and match the size of the object being measured with the spatial resolution. Pay attention to the thermal sensitivity parameter and environmental adaptability to ensure the instrument's response speed meets dynamic detection requirements. Determine the image frame rate and lens configuration based on the application scenario, and conduct a comprehensive evaluation by combining data analysis capabilities with ease of operation.

Terms

Standards

Instruments

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.

$ 2494.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.

$ 2494.00

The transient planar heat source method is used, the test time is not more than 160 seconds, the Sensitivity is 0.00001, and the thermal conductivity of 0.0001 to 50W/(m * K) can be measured. It supports a variety of morphological samples and meets international standards.

$ 12983.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.

$ 2368.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.

$ 507.00

Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.

$ 1510.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.