A colorimetric light box

A color matching light box simulates standard lighting conditions such as daylight and store lighting to provide a stable and uniform illumination environment. It is used for color comparison of samples such as paints and plastics, eliminating interference from ambient light and ensuring consistency in visual evaluation. It finds applications in quality inspection, color matching, and production process control.
Selection
When selecting, consider matching the light box size to the sample dimensions, ensuring the light source types cover common standards such as D65 and TL84. Illuminance uniformity should be stable, and the interior of the box should be coated with neutral gray to avoid reflective interference. The operation interface should be user-friendly, with convenient timing functions and easy light source switching.

Terms

Standards

Instruments

Measurement range 0~ 150mg/L, 10mL Colorimetric Encasement, 25/box, suitable for rapid detection of chemical oxygen demand in water quality.

$ 169.00

The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, digests Colorimetric integrated tube to make the measurement safe and fast, can store 4000 sets of data and support multi-mode power supply.

$ 4721.00

The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, is equipped with a digestion Colorimetric integrated tube to achieve safe and fast measurement, and has 4000 sets of data storage and a variety of transmission interfaces.

$ 5528.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illumination up to 3000LX, life more than 10,000 hours, uniform irradiation surface and no stroboscopic, flexible adjustment of light box position and angle according to test requirements.

$ 12305.00

Adopt digestion Colorimetric integrated tube design for safer and more convenient detection; minimum display value of 0.001mg/L, high Sensitivity; built-in rechargeable lithium battery, support long standby, power only 0.3W, strong portability.

$ 4882.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Built-in mobile slide table can move the camera front and rear, high display finger no stroboscopic LED Illuminant Color temperature is stable, the illuminance is adjustable, the back plate of the box can post 712mm * 400mm test card to provide a uniform lighting environment.

$ 4592.00

Measurement range 0~ 1500mg/L, 10mL Colorimetric tube Encasement, 25 boxes convenient for batch use, suitable for water quality chemical oxygen demand detection and analysis.

$ 169.00

Adopt digestion Colorimetric integrated tube design, detection limit of 0.02mg/L, support 125 ℃ closed digestion, built-in imported cold light source life of 100,000 hours, can store 4000 sets of data and support multi-mode power supply.

$ 2203.00

Colorimetric measurement using ferrous sulfate method, Measurement range 0~ 150mg/L, providing 100 tests to ensure accurate determination of nitrite concentration.

$ 202.00

Colorimetric digestion integrated tube operation, no need to transfer liquid, Measurement range 0~ 250mg/L, detection limit of 0.5mg/L, multiple measurements of water samples to take the average value to reduce errors, suggesting detection of abnormalities.

$ 2913.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illuminance adjustment range 0-3000LX, life of more than 10,000 hours, uniform irradiation without stroboscopic.

$ 7464.00

Colorimetric integrated tube design is adopted, with a detection limit of 0.5mg/L, high temperature digestion at 125 ° C, built-in 4000 data storage and a variety of transmission interfaces to meet the needs of on-site rapid detection.

$ 2913.00

Articles

Taber Abrasion Test Method for Wear Resistance of Coating Films
This article introduces the Taber abrasion test method, which is used to evaluate the ability of coatings, such as those on floors, furniture, or car interiors, to resist mechanical wear.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Shore hardness tester measures the hardness of rubber sealing rings.
This article introduces the method of measuring the hardness of rubber sealing rings using a Shore durometer. The Shore durometer presses a needle into the rubber surface under spring force and converts the indentation depth into a hardness value, commonly using the A scale.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
The Taber stiffness tester is used for measuring the bending stiffness of paperboard.
The Taber stiffness tester is used to measure the bending stiffness of paperboard. Its principle involves applying a known bending moment to the specimen and measuring its resistance to deformation. Bending stiffness is a key performance indicator of paperboard, affecting its processing suitability and packaging functionality.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Standardized ink color evaluation environment for visual color comparison cabinets
This article introduces the standardized application of visual color comparison boxes in ink color evaluation. It emphasizes that to ensure the accuracy and consistency of color judgments, the evaluation environment must be strictly controlled.