Measurement range 0.0-15 ppm, accuracy +/- 0.3ppm +/- 5% reading, using LED@525nm Illuminant, based on amino acid method for rapid detection of phosphoric acid salts, easy to operate and suitable for laboratory and field.
Using 525nm LED Illuminant, Measurement range 0.0-30 ppm, accuracy +/- 1.0ppm, based on amino acid method to achieve high Sensitivity phosphoric acid salt detection, suitable for a variety of water quality environments.
Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.
The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.
Using stainless steel material to ensure acid and alkaline resistance, wet film thickness 100μm accuracy of +/- 2μm, suitable for a variety of pRoduct coating and in line with industry standards.
The stainless steel material has acid and alkaline resistance, wet film thickness 75μm accuracy +/- 2μm, suitable for coating applications of various substrates.
Using stainless steel material with acid and alkaline resistance, wet film thickness 250μm accuracy of +/- 2μm, suitable for flat and sturdy substrate film operation.
Made of stainless steel with good acid and alkaline resistance, wet film thickness 150μm accuracy +/- 2μm, suitable for a variety of pRoducts on flat substrates Spreader applications.
Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.
Using stainless steel material acid and alkali resistance, wet film thickness 25μm accuracy +/- 2μm, suitable for flat substrate coating, in line with ASTM multiple test standards.
Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.
Using 525nm LED Illuminant to ensure Stability, Measurement range 0-200ppb, accuracy +/- 5ppb, support ascorbic acid detection, with Automatic calibration verification function.
Using stainless steel material acid and alkali, wet film thickness 50μm accuracy +/- 2μm, suitable for flat and solid substrate coating different pRoducts, surface polishing.
Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, surrounded by 316L stainless steel material comprehensive corrosion resistance.
The samples were treated by acid-base cooking method, and 6 samples could be measured each time. The repeatability error of the absolute value of crude fiber content below 10% did not exceed 0.4%, and the determination time was about 100 minutes.