Water Quality Chloride Ion Content Detector

The water quality chloride ion content detector measures the concentration of chloride ions in water using the electrode potential method. The electrode reacts with chloride ions to generate a potential difference, and the instrument converts the signal into a concentration reading. It is used to monitor chloride ion levels in drinking water, industrial wastewater, and other water bodies to ensure water quality meets usage standards.
Selection
When selecting, consider that the measurement range should cover actual needs and the precision should meet testing requirements. Electrodes need to be replaced regularly, and the operating interface should be simple. Ensure the instrument supports common water sample types, with moderate maintenance costs and consumable prices. Compare by referring to feedback from existing users.

Terms

Standards

Instruments

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Designed for chloride ion composite ElectRode, provides stable calibrating performance, Encasement size 250ml, to ensure long-term use Reliability and measurement conformity.

$ 110.00

Adopt automatic potential Titrimetric method, built-in standard method to directly read the results, support silver nitrate (AgNO3) calibration and blank experiment, data management can store 200 sets of results, titration analysis Repeatability of 0.20%.

$ 3667.00

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

Using composite ElectRode design, equipped with special reference filling solution and calibrating solution, Measurement accuracy is high, BNC interface compatibility is strong, suitable for a variety of water quality analysis scenarios.

$ 309.00

Specially designed for lead chloride ion composite ElectRode, providing stable reference potential to ensure the accuracy of ion measurement, Encasement capacity 250ml, suitable for routine laboratory testing.

$ 99.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, Measurement accuracy +/- 1% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration and water Hardness detection.

$ 864.00

General ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE solution bottle Encasement, capacity 480mL, water Hardness type.

$ 135.00

Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.

$ 164.00

1000Pppm standard concentration to ensure the accuracy of calibrating, PTFE material solution bottle effectively prevent contamination, 480mL capacity to meet the needs of conventional use, universal design for a variety of ion measurement scenarios.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and 2 to 5 point calibrating, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F.S.

$ 864.00

ElectRode composite design, Measurement range, Response fast and stable, equipped with special reference filling solution and calibrated solution to ensure measurement accuracy, suitable for a variety of water quality analysis scenarios.

$ 273.00

Designed for fluoride ion detection, 250ml standard Encasement provides a stable ionic strength environment to ensure ElectRode measurement accuracy and Repeatability, suitable for a variety of water quality analysis scenarios.

$ 127.00

Optical inspection Colorimetry is used to eliminate human error, the measurement resolution reaches 0.1mg/L, Repeatability ≤ 2%, suitable for all kinds of water urea content detection.

$ 309.00

Optical inspection Colorimetric detection principle, eliminate human error, measurement resolution of 0.1mg/L, Repeatability ≤ 2%, suitable for indoor and outdoor water quality testing environment.

$ 240.00

Articles

Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.