Aluminum material, 37ml volume, in accordance with GBT21862 and ISO 2811 standards, the cover is designed with holes to facilitate excess liquid overflow, ensuring accurate measurement.
With low temperature OLED display, it can still work normally in -40 ℃ environment; equipped with iron-aluminum dual-use Probe, automatically identify the substrate and convert the mode; Measurement speed is as fast as 0.5 seconds, error range +/- 3%.
The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.
Film thickness 0.5mm, rounded edges without burr design, surface with anti-rust oil, suitable for adhesion, hardness, Impact and other paint performance testing experiments.
Konig and Persoz swing bars are used, Konig swing period is 1.4s, Persoz swing period is 1s, and the number of swing angles is automatically recorded, which is suitable for accurate determination of paint film Hardness.
Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.
It can measure the minimum inner diaMeter of 6mm aluminum tube and 8mm thickness profile, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, support Hardness value multi-standard conversion.
Enclosed aluminum silicate Furnace and nickel-chromium-aluminum alloy heating wire are used to reduce volatile gas corrosion; three-sided heating method combined with PID control, Temperature Fluctuation +/- 5%, accurate and stable temperature control.
The activated aluminum oxide ball is used as the adsorption medium, which can adsorption water vapor and chemical corrosion harmful gases, and the oil blocking rate is more than 99%.
Three-sided heating method with aluminum silicate Furnace, high thermal efficiency and uniform temperature. PID control combined with K-type Thermocouple, temperature control accuracy +/- 5%, support 0~ 9999 minutes timing and phased heating.
Using titanium anodic oxidation aluminum material, the filter is stainless steel, the diaMeter of the flow hole is 4.1mm, the viscosity range is 70-370cSt, the Cup mouth is designed with an anti-spill groove, and each Cup is engraved with a unique serial number.
With double-decked anodic oxidation aluminum housing structure, temperature control is achieved by chilling down and heating liquid, suitable for a variety of standard viscosity Cups, hard anodic oxidation aluminum and stainless steel materials to ensure durability.
Made of aluminum alloy, with a size of 50 * 50mm and a clamping diaMeter of 16mm, it has a lifting adjustment function and a stable and durable structure.
With 15 °, 45 °, 110 ° three-angle measurement function, can simultaneously obtain Color data, flicker and particle grade; built-in automatic white calibrating, no human intervention; with stable long-life LED Illuminant, the service life is up to 10 years.
Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.