Pulsating Pressure Steam Sterilizer

The pulsating pressure steam sterilizer removes air using a vacuum pump and then injects saturated steam, utilizing high temperature and high pressure to denature microbial proteins. It is used for sterilizing heat-resistant items such as laboratory instruments and culture media, ensuring a sterile state in medical and biological laboratories.
Selection
When selecting, consider matching the sterilization chamber volume to the item load capacity, ensure the material is corrosion-resistant, review data on temperature uniformity and pressure stability, confirm the completeness of protective devices such as safety valves and temperature sensors, verify that the power specifications match the usage site, and pay attention to the convenience of daily maintenance and consumable replacement.

Terms

Standards

Instruments

Irreversible discoloration records the highest temperature, accuracy +/- 1 ° C to +/- 4 ° C, four-speed temperature monitoring range 104-121 ° C, oil-resistant, water-resistant and steam-resistant, instant Response without power supply.

$ 93.00

Irreversible Color change for long-term temperature recording; Resistant to oil, water and steam; Temperature accuracy is +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C; Self-adhesive design for easy use and storage.

$ 93.00

Adopting the principle of irreversible discoloration, the accuracy is +/- 1 ° C below 100 ° C, with 6 temperature grids from 65 ° C to 93 ° C, oil, water and steam resistance to ensure stable operation in harsh environments.

$ 93.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

Manual pressure control pressure holding operation is simple, electronic pressure holding device reduces mechanical abrasion, pressure range 0~ -90kPa, accuracy +/- 0.1kPa, Organic Glass sealing barrel wall thickness 15mm to enhance compressive strength.

$ 887.00

Using electric pressure system and circular pressing operation mode, printing pressure 0-4mm, speed 0-100 Meters, adjustable scraper pressure and speed, support low accuracy overprinting and Color detection.

$ 6020.00

Using R2.5mm steel ball to apply 20N pressure, test at standard temperature for 60 minutes and then evaluate the thermal deformation performance of the material through measurement of Crane diaMeter, which is suitable for testing of various electrical components.

$ 196.00

Using high elasticity standard rubber and denim for extrusion test, extrusion pressure 10-120kgf adjustable, Test speed 5-30 times/minute, to meet the requirements of YD/1539-2006 standard.

$ 1079.00

Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.

$ 1066.00

Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.

$ 482.00

The pressure column and ball joint structure are used to ensure that the test surface is close, the pressure column mass is 250g, the bottom surface diaMeter is Φ 50 +/- 1mm, and it is equipped with 100g to 500g weight, which can simulate the contact performance of coatings under different pressure conditions.

$ 283.00

High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.

$ 562.00

Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.

$ 611.00

Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.

$ 838.00

Fully automatic test with microcomputer control, pressure range 0~ -90kPa accuracy +/- 0.1kPa, equipped with 15mm thick Organic Glass sealing barrel and precision pneumatic components, support automatic constant pressure air replenishment and multi-point pressure calibrating.

$ 1453.00

Articles

The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Sealing tester measures the pressure resistance and leakage of composite film bags.
This article introduces how to use a seal tester to evaluate the pressure resistance and leakage performance of composite film bags. The test primarily involves applying controlled pressure inside the packaging and observing pressure changes or leakage to assess the quality of the seal.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
Key Parameters for Air Compressor Selection and Analysis of Energy Efficiency Standards
The selection of an air compressor requires comprehensive consideration of discharge pressure, discharge volume, drive power, and the characteristics of the compressed medium to meet actual air usage requirements.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
The melt flow indexer measures the flow rate of thermoplastic resins.
A melt flow indexer is a device used to measure the flowability of thermoplastic resins. It calculates the melt flow rate by determining the mass or volume of the melt that passes through a standard die within 10 minutes under specific temperature and pressure conditions.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.