Low-temperature Drying Oven

The low-temperature oven heats via electric heating elements and maintains a constant temperature environment between 40-150℃ with a temperature control system. It utilizes hot air circulation to accelerate moisture evaporation or curing reactions in samples. It is used for processes requiring gentle heating, such as paint curing, plastic aging tests, and paper drying.
Selection
Determine the temperature range and uniformity requirements based on sample characteristics; consider the corrosion resistance of the inner chamber material; verify the compatibility between the volume and sample size; select a temperature control system with over-temperature protection; balance energy consumption and space occupancy.

Terms

Standards

Instruments

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Temperature control accuracy of +/- 1 ℃, Temperature Uniformity +/- 2 ℃, with overheating alarm and timing function, low noise hot air circulation system to ensure uniform drying, optional RS-485 interface connection recorder.

$ 449.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, fast and low consumption, equipped with thermistor temperature control, the studio is made of 304 stainless steel, size 750 * 600 * 600mm, easy to adjust, suitable for drying treatment of various samples.

$ 840.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Temperature control accuracy of +/- 1 ℃ and uniformity of +/- 2 ℃, using low noise hot air circulation system directly drying objects, with over-temperature alarm and 1-9999 minutes timing function, support RS-485 communication interface to record data.

$ 415.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, temperature control accuracy +/- 0.5 ℃, volume 23L, suitable for powder or particle sample drying, low energy consumption and convenient maintenance.

$ 1048.00

Temperature uniformity is improved by air circulation system, temperature control accuracy is +/- 0.5 ℃, Temperature resolution is 0.1 ℃, mirror stainless steel liner ensures durability and easy cleaning, suitable for a variety of drying applications.

$ 435.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control, fast low consumption, suitable for a variety of sample drying.

$ 756.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast drying, low energy consumption and easy adjustment, suitable for a variety of Sample Handling.

$ 581.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, with forced warm air circulation to ensure uniform temperature, optional RS-485 interface to record temperature changes.

$ 971.00

Large LCD screen, Menu Operating interface, Temperature Fluctuation +/- 1 ℃, Mirror stainless steel liner for easy cleaning, Thickened box design low surface temperature, Thermal Power reduced by more than 25%.

$ 803.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.